7.1.1 Rotating the reservoir (AS2, AS3, AS5)

1. Remove the reservoir.
2. Rotate reservoir 180° and click it back into place.
The release is now pointing to the front.

7.1.2 Converting the filter

On all components, the flow direction is changed by installing the components
rotated by 180° around the vertical axis.
This requires the housing covers to be changed.
INFO: On series AS1 no conversion is required.
The "right/left flow" version has a separate order number.
Replacing the housing cover (AS2, AS3, AS5)
1. Release the housing cover at the front and back.
2. Attach the cover on the opposite sides.
The cover bearing the AVENTICS logo is facing forwards.

7.2 Mounting the AS contamination display

See g Fig. 7
1. Release the screws (b) on the filter housing (a) and remove the cover (c).
2. Insert the seals 4 x 1.5 according to DIN 3771 (d).
3. Place the contamination display (e) on the filter housing and tighten the
screws (f).
Max. tightening torque: 1.5 Nm, M5 x 20 according to DIN 965

8 Cleaning and servicing

• Close all openings with suitable safety devices so that no cleaning agent can
enter into the system.
• Never use solvents or aggressive detergents!
• Do not use high-pressure cleaners for cleaning!
• Do not use compressed air for cleaning (blowing off) the maintenance unit or
equipment.

9 Disposal

Dispose of the product in accordance with the national regulations in your coun-
try.

10 Troubleshooting

Malfunction
Possible cause
Pressure/flow level is not
Filter contaminated
reached or drops off slowly.
Selected filter size too small
Contamination display al-
Flow rate too high
ready indicates red on first-
time commissioning.
Contamination display indi-
Soiled filter
cates red during operation.

11 Technical data

This section contains an excerpt of the key technical data. Further technical data
can be found in the online catalog.
General
Maximum permissible pressure, temperature range, and thread connection are
indicated on the products.
Specifications
Mounting orientation Vertical
Medium/ambient
-10 – +50°C
temperature min./
max.
min. ... max.
AVENTICS™ AS1 / AS2 / AS3 / AS5 | R412013436-BAL-001-AF | English

12 Appendix

Fig. 1: Condensate drain | Series AS1, AS2, AS3, AS5
I: Semi-automatic condensate drain, II: Fully automatic condensate drain, III:
Manually draining condensate
Fig. 2: Wearing parts
I: AS2 – AS5 FLS; II: AS1 FLS; III: AS1 – AS5 FLP/FLC/FLA
Remedy
Clean or replace filter
Select larger filter
Use larger series; reduce flow
rate
Clean or replace filter
Fig. 3: Exchanging the filter |
Series AS1 FLS
Figures: View varies according to the series.
II
I
I
II
a
a
b
b
a
a
a
g
f
III
III
c
c
d
b
e
i
h
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aventics as2Aventics as3Aventics as5

Table of Contents