Evacuating Products Of Combustion; Models For Indoor Installation; Models For Outdoor Installation; Electrical Connections - Beretta Idrabagno Lx Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
ENGLISH
See Fig. 25
b
For the minimum distances from combustible materials, see what
is reported in Fig. 27
See Fig. 27

3.4 Evacuating products of combustion

3.4.1 Models for indoor installation

exhaust/air intake kit is not supplied with the boiler as accessories for
sealed-chamber forced-draught appliances, which better adapt to the in-
stallation context, can be used.
use original piping or others with the same characteristics which are EC
appliance is sealed chamber type.
appliance cannot operate.
"FORCED OPEN" INSTALLATION (B22-B52)
according to installation requirements.
For installation, follow the instructions supplied with the kit.
b
where the appliance is installed, which should be technically suita-
ble and ventilated.
b
danger.
b
The table indicates the permitted linear lengths.
Maximum length
Model
Ø 80 mm (m)
11-13
15
17
6
See Fig. 28
COAXIAL DISCHARGES (60-100 Ø)
The boiler has been designed to be connected to concentric discharge/
suction pipes and with the opening for air suction ( D
installation room, in line with the lengths shown in the table.
For installation, follow the instructions supplied with the kit.
b
The table indicates the permitted linear lengths.
Horizontal
Maximum length
Model
Ø 60-100 mm (m)
11-13
3,5
17
2,6
Vertical
Maximum length
Model
Ø 60-100 mm (m)
11-13
4,5
17
3,6
See Fig. 29
18
-
-
Loss of load (m)
45° bend
90° bend
1,2
1,7
1,2
1,7
Loss of load (m)
45° bend
90° bend
1
1,5
1
1,5
Loss of load (m)
45° bend
90° bend
1
1,5
1
1,5
SPLIT PIPE OUTLETS (80 Ø)
Twin outlets can be placed in the most suitable direction according to the
room requirements.
The combustion air intake pipe must be chosen from the two inlets ( E and
F
for the chosen input.
The air inlet adaptor Ø 80 ( E
with the casing.
b
The table indicates the permitted linear lengths.
Maximum length
Model
Ø 80 mm (m)
11-13
15+15
17
6+6
See Fig. 30 and Fig. 31
Fig. 32 and Fig. 33 show the water heater from above with the
respect to the water heater support plate.

3.4.2 Models for outdoor installation

For information on evacuating the products of combustion, please refer
to UNI 7129.
gases or a suction line for combustion air.
The combustion gases are expelled directly into the air by the integrated
outlet.
See Fig. 34
a
Avoid inhaling combustion gases.
a
Avoid direct contact with the combustion gases since they can
reach extremely high temperatures that can cause burns.
a
Avoid direct contact with the discharge since it can reach extremely
high temperatures that can cause burns.
a
To ensure the combustion gases are expelled correctly, it is forbid-
a
It is forbidden to loiter near the appliance when it is operating.

3.5 Electrical connections

Connect the cable supplied to the line, respecting the phase, neutral and
earth wiring. Should the power cable need to be replaced, this must be
2
ground wire must also be 30 mm longer that the power cables. Power
to the appliance via an omnipolar switch with a gap of at least 3 mm
between contacts. For maintenance operations, cut the voltage by using
the omnipolar switch.
b
We decline all responsibility for damage to persons, animals or
electrical system that complies with the standards in force.
for the appliance's maximum absorbed output, as shown on the plate,
ensuring particularly that the section of the system cables is suited to the
appliance's absorbed power.
Adaptors, multiple sockets or extensions should not be used to connect
the appliance to the main power supply.
Loss of load (m)
45° bend
90° bend
1,2
1,7
1,2
1,7

Advertisement

Table of Contents
loading

Table of Contents