End Of Season Maintenance; Replacing The Batteries - Unical Air UND A 9H Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

6

END OF SEASON MAINTENANCE

·
Disconnect the automatic switch or the plug.
·
Clean and replace the filters.
·
On a sunny day let the conditioner work in ventilation for some hours, so that the inside of the unit dry
completely.

REPLACING THE BATTERIES

7
·
When:
There is no confirmation beep from
the indoor unit.
·
The liquid crystal display doesn't
activate.
·
How:
Take off the small lid downward as
from the drawing.
·
Place the new batteries respecting the
symbols + and -.
·
N.B.
Use only new batteries.
·
Remove the batteries from the remote
control when the conditioner is not
used.
WARNING! Do not throw flat batteries with common rubbish, they should be disposed of in the special contai-
ners situated in the collection points.
IF THE CONDITIONER DOESN'T WORK
8
1. If the conditioner doesn't work, control the voltage of the mains:
·
Is the plug inserted properly?
·
Has the automatic circuit-breaker intervened?
·
Has there been a power failure?
Note: if there is a power failure, the conditioner switches off: when the power returns, the air conditioner
will restart automatically.
2. If the cooling (or heating) effect seams less
than normal:
·
Has the temperature been correctly set on the control
·
Has a door or a window been opened?
·
Is the indoor unit directly exposed to the sunlight?
·
Are the filters clogged?
·
Are there obstacles hindering the free air circulation from the indoor unit or to the outdoor unit?
Unical garantisce la conformità dei climatizzatori alle norme relative alla sicurezza del prodotto secondo le Direttive Europee.
_
+
Size AAA 1,5V
OPEN
_
+
1,5 V
_
+
1,5 V

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Und a 12hUnd a 18hUnd a 24h