E L E C T R O N I C C I R C U I T S
HOURS CONTROLLER.
The CD-34 module is an automatism to monthly control and follow the operating and yield of the
apparatus, device. It has been specially designed to obtain a fast and accurate resume of the labour
calendar done by the controlled machine.
It indicates the hour to start the count, the starting date, the total worked hours, labour days, average per hour,
hours per day, operating time (per day, week, month).
Data are showed on a 13,5 mm display. It includes battery to maintain data when the module is not
connected (supplied), indicator leds, control buttons, front panel and terminals to make more easy the
TECHNICAL CHARACTERISTICS.
Voltage. ..........................................................................................From 9 up to 12 V. DC.
Minimum Consumption. ................................................................70 mA.
Maximum Consumption. ...............................................................100 mA.
Hour Format. ................................................................................. 24 H.
Date Format. ................................................................................. Day, month and year.
Intermittent Time Hour / Date. ..................................................... 5 sec.
Display. .......................................................................................... 6 x 0,5" Displays (13.5 mm.) and leds.
Battery. .......................................................................................... CR-20 (3 V.)
Protection Against Polarity Inversión. ............................................. Yes.
OPERATING.
POWER SUPPLY. The CD-34 module had to be supplied
reason we recommended you the FE-71 power supply which has been developed to perfectly answer to the circuit
needs.
Connect the positive of the power supply to the positive terminal indicated in the wiring map, then connect also
the negative of the power supply to the negative terminal indicated in the circuit.
Verify that the assembly has been correctly done and activate the power supply.
OPERATING. The CD-34, as module specially designed to control yield, could be used on restricted mode, to
avoid to modify data because of a wrong manipulation and/or an accident. For this reason, the keyboard usually
used to display data could be used to activate, stop or reset the module's count only when you wish it. Then, the
employe even if he uses the keyboard for other applications, he could not have access to activation, Stop, Reset
Time adjustment functions.
PREPARATION OF THE MODULE. ACTIVATION, STOP , RESET AND HOUR ADJUSTMENTY. To have access to these
Batter y
JP1
JP1 Jumper on the PCB
CD-34
CD-34
by a 9 - 12 V DC. power supply perfectly stabilised, for this
Connect for following functions:
Lateral View of the JP1 Jumper
1
connected
Activation.
Stop.
Reset.
Hour Adjustment.
JP1