Instruction FH-CWP Thermostat
7. Choosing room temperature
control or both room and floor
temperature control
Turn OFF the thermostat by pressing
Fig. 1.
• Press
Fig. 1 and
Fig. 1 for 10 seconds.
The display will show 01.
• Press
Fig. 1 to adjust desired controltype.
01=room temperature control, only with room sen-
sor, no floor sensor, check and setting only room
temperature.
02=both room and floor temperature control, with
room sensor and floor sensor, check and setting
room temperature and maximum floor tempera-
ture limit.
Factory setting is 01.
8. Maximum floor temperature
protection (Optional)
The function allows you to set a maximum allow-
able floor temperature if for instance you want
to protect real wood floors from damage due to
excess heat. For specific maximum floor tempera-
tures please refer to recommendations from floor
suppliers.
15
Produced by Danfoss Floor Heating Hydronics 05.2011
VI.CU.C2.2D