Download Print this page
Vimar ELVOX 41018 Installer's Manual

Vimar ELVOX 41018 Installer's Manual

3.5 in
Hide thumbs Also See for ELVOX 41018:

Advertisement

Quick Links

Installer guide
41018
Display 3.5 in

Advertisement

loading
Need help?

Need help?

Do you have a question about the ELVOX 41018 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vimar ELVOX 41018

  • Page 1 Installer guide 41018 Display 3.5 in...
  • Page 2: Table Of Contents

    ENGLISH The instruction manual can be downloaded from www.vimar.com 3.5 in display for audio or audio-video modules, 3 buttons for calls from contacts list backlit with white LEDs, 1 input configurable as external but- ton for CA door opener or PA door open, to be completed with front cover Contents BRIEF DESCRIPTION OF DEVICE ART.
  • Page 3: Features

    FEATURES 2.1. Features • The 3.5" display has the following features: 320 x 480 pixels, 65K colours, 500 lux. • The device must always be accompanied by an audio video module 41003, 41004 or an audio module 41001 (except for the basic audio module 41000). •...
  • Page 4: Configuration Via Pc

    CONFIGURATION VIA PC 3.1. Programming the Contacts List and entry control codes The contacts list (up to 8192 items) and the entry control codes (up to 2000 codes) can be programmed via the PC programming SW (SaveProg), connecting to the audio/video module. Follow the instructions given on SaveProg.
  • Page 5 3.2.2. Building filter This filter lets you access the subset of users paired with a specific building. Users Porter Buildings Contacts Extension The Building filter can be combined with the names pre-filter. Users Users Porter Buildings Contacts Extension 3.2.3. Stair filter The Stair filter lets you access the subset of users paired with a specific stair or all users.
  • Page 6 3.3. Additional information Additional information is displayed on a contacts list entry when the user hovers over it for more than 3 s. Can be managed via SaveProg, by enabling the flag. In order of priority: • if present, the string of the User Information field is displayed •...
  • Page 7: Configuration Via Menu

    CONFIGURATION VIA MENU The display provides the ability to configure the basic parameters of the panel. There are two menus: 1. administrator: the administrator side lets you modify the display module interface; 2. installer: lets you change some of the functional parameters of the panel. You access the menu by simultaneously pressing for 5 s and entering the respective pass- (UP)
  • Page 8 Porter Porter Contacts Contacts Select Navigation Direct • Font: Normal/Large Changes the font size, to improve readability. PORTER Porter Contacts CONTACTS EXTENSION Extension SELEZIONA SELECT Normal Large 4.1.3. LCD This lets you define the operating parameters of the display • Brightness: 0-5 Brightness level.
  • Page 9 Label Settings Level 0 Level 1 Level 2 Italian, English, French, German, Spanish, Greek, Language Portuguese, Russian, Swedish, Dutch and Polish (Default: Italian) Menu Navigation Navigable/Direct (Default: Navigable) Display Font Normal/Large (Default: Normal) Brightness 1-5 (Default:5) Colours B/W, BLUE, GREEN (Default: B/W) Standby ON/OFF (Default: ON) Speaker...
  • Page 10 Starts the procedure of assigning the order of the button modules. • Grouping: Single rocker, single axial, double axial button Lets you choose the type of grouping of the panel. 4.3.3. Addressing This lets you start the panel and indoor unit addressing procedures. •...
  • Page 11: Using The Display Module

    USING THE DISPLAY MODULE In standby mode the device gives the instructions to follow to access the available features depending on the type of installation. Depending on the programming of the contacts list and the presence of an alphanumeric keyboard, the main screen of the display module will show the switchboard, contacts list and entry code items.
  • Page 12 Clearing the name being formed, with button C, restores the initial view. The multi-tap function is only active if the pre-filter by initial is not active. 5.2. Calling a Switchboard To call a switchboard there is a quick item in the main menu. In addition, any other switchboards are accessible as contacts list entries.
  • Page 13 5.4. Call information The device returns the status information associated with the call phase: Calling Talking No answer Call ended Porter Back Delete Back Delete Concluded No Reply If the system is busy, with another call, the wait signal is returned: Busy If the user is busy or has set the user absent service, these warnings are issued: Busy...
  • Page 14 5.5.1. Operation The keypad has 2 function keys referred to here as Press the button and the display to go into “Code Entry” mode. Each time a digit button is pressed, the display will show the digit for a short time and then overwrite it with an aster- isk.
  • Page 15 Check the module connections and restart the electronic unit. Upgrade the modules Upgrade the display module and the audio video module to the latest FW release, which can be downloaded from the Vimar website. Comm. Error If the problem persists, please contact customer service.