Note:
If no air is bubbling from the one-way bleed valve, this is a good indication that the
positive air purge system is not working.
11.
Use a pocket screw driver to remove the black washer
assembly. Save this washer as it can usually be reused. Be careful not to scratch the metal
surface under the washer.
12.
Use a pocket screwdriver to remove the retaining ring or star washer
filter
3
in place. Always discard the used inlet filter. The retaining ring is saved for reuse.
13.
Remove the moving orifice assembly
probe (p/n TL111) from the large threaded end of the body. Catch the orifice assembly in your
hand as it comes out the yoke nut thread end of the body. Carefully inspect the disc springs
for any cracks. Replace all five disc springs if any cracks are found.
14.
Remove the one way bleed valve
DO NOT use a metal screwdriver or blade since this will scratch the sealing surface against
which the bleed valve seals. A scratch may allow water to enter the first stage spring chamber
during use.
17
that was beneath the element
4
from the body by pushing it with the Sherwood plastic
15
from the body with your fingers or a soft plastic probe.
7
Photo #2
2
that holds the inlet
5