Configure Surface Panels Id, Ip Addresses & Subnet Masks - Calrec TYPE R Startup Manual

Hide thumbs Also See for TYPE R:
Table of Contents

Advertisement

6. CONFIGURE SURFACE PANELS ID, IP ADDRESSES & SUBNET MASKS
IM6413 TYPE R - 6 WIDE FADER PANEL
TOP & REAR VIEWS
1. Carefully remove the surface panels and cables from their packaging. If there are any signs of damage, please contact
Calrec Customer Support and do not continue to use the damaged parts.
2. If panel stands or brackets were purchased, you may want to fit these to your panels now.
• Please refer to the Type R Installation manual for more information on stand and bracket assembly.
3. Set each panel ID using the switches on the rear of the panel.
• The 8-way DIP switch is set as an 8-bit binary representation of the ID value. Each switch is labelled with a value on the
panel metalwork. Positioning a switch in the on (1) position enables this value. The values of all enabled switches are
summed to create an ID between 1 and 255.
• Each panel requires a unique ID. Please refer to
4. Using the cables supplied, connect each panel to a POE+ switch or POE injector to power it on.
5. Panels set with factory default settings should boot into config mode automatically. To enter config mode manually, follow the
instructions below:
• Fader panels: hold down the first 3 buttons on the bottom button row before powering during panel boot up.
• LSP: hold down the first 3 buttons once the Calrec logo appears during panel boot up
• SSP: hold down the large button and encoder once the Calrec logo appears during panel boot up.
6. When the panels have entered config mode, set each panel's IP address and subnet mask following the instructions below:
• Fader panels: Press option 8 "Set IP Addr" and use the rotary controls to enter each value, then press any Save button.
• Soft panels: Press Edit next to the IP address then enter a new value using the on-screen keyboard. Note that the subnet
mask on soft panels is not currently editable and is defaulted to the suggested setting (255.255.0.0, or /16 in CIDR notation).
7. Press Reboot to accept changes and on completion disconnect each panel.
MU6411 TYPE R - LARGE SOFT PANEL
TOP & REAR VIEWS
"Surface Panels - Suggested Settings" on page 24
MU6410 TYPE R - SMALL SOFT
TOP & REAR VIEWS
PANEL
13

Advertisement

Table of Contents
loading