PW-7000 Two-Reader Module Wiring: Connectors 1, 7-9
Connect to
chassis GND
at one side
ONLY !
RS-485 Com
Bus Cable
From Diff.
Panel
(Remote)
NC
RS-485 TR+
RS-4845 TR-
RS-485 GND
+ 12V
GND
Note: For RS-485 Communication Connections, twist the blue pair together and use as the
common; use the orange pair as your data pair, observing polarity. Connect the
external drain shield to the appropriate earth ground on one end.
16
TWO READER BOARD
1
2
3
4
1
2
3
D15
4
5
6
7
8
D5
D9
D6
D10
9
D7
D11
10
D8
D12
D19
1
J 2
2
3
4
5
6
1
2
3
D17
4
5
6
7
8
9
10
D16
1
J 3
2
3
4
5
J 1 - RS-485
6
Termination
1
D1
2
D2
D3
3
D4
4
5
PW-7000 Two-Reader Module Installation Guide, Document 800-25676V1
1
2
3
1
2
3
4
D18
1
2
D13
3
D14
4
5
6
D20
Self-Powered
Audio / Visual
Alarm Indicator
Tamper Switch
(In CLOSE
position when
Cabinet Door is
Closed)
TMP
GND
PFL
IN6
IN6 Common
IN7
IN7 Common
Relay 4 NC
Relay 4 C
Relay 4 NO
Relay 5 NC
Relay 5 C
Relay 5 NO
NO
C
The connectors on this
side of the board are not
accessible when it is rack
mounted.
PWR+
PWR-
+12VDC Power
Supply
C - No Charging
N/C - No Charging
N/C - Low Battery
C - Low Battery
PWR+
+
_
DC Output
PWR-