Led Operation - Honeywell Pro-Watch 7000 Install Manual

Two-reader module
Hide thumbs Also See for Pro-Watch 7000:
Table of Contents

Advertisement

S8
OFF
* = Default

LED Operation

The Two-Reader Module uses two onboard LEDs (D1 and D2) to provide status
information during the power-up sequence as well as during normal operation. The
Two-Reader Module also uses two onboard LEDs (D3 and D4) to indicate reader
activity.
Table 3: Onboard LEDs
Mode
Power-up
sequence
Normal Opera-
tion
In addition to the status LEDs, there are six additional relay status LEDs and eight
input status LEDs on board. The input LEDs flash when there is a fault associated
with the input. When any relay or input is energized or ON, its corresponding status
LED becomes ON also. The LED remains ON for as long as the relay is energized.
The assignment for each relay status LED is shown in the following table.
12
S7
S6
S5
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
LED
LED
Description
D1
D2
ON
OFF
Start power-up, hardware setup.
OFF
ON
Testing RAM.
ON
ON
Testing ROM and completing initialization.
FLASH
ON
LED D1 flashes four times after power-up is completed.
FLASH
This is the processor heartbeat LED. It flashes once every second. A short ON
time (~20% duty cycle) indicates the board is offline or has lost serial
communication with the Controller board. A long ON time (~80% duty cycle)
indicates the board is online and communicating with the Controller board.
FLASH
Flash when there is activity on its Serial Port.
PW-7000 Two-Reader Module Installation Guide, Document 800-25676V1
S4
S3
S2
S1
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
Selection
ADDRESS 25
ADDRESS 26
ADDRESS 27
ADDRESS 28
ADDRESS 29
ADDRESS 30
ADDRESS 31
Reserved
9,600 BPS
19,200 BPS
38,400 BPS*
Not Used*