4.10.
Resetting the Batch Total
4.10.1.
While in standby (i.e. when display shows TOTAL) press the RESET button, see fig.11.
fig.11
4.10.2.
during reset the display screen shows all the digits lit up, see fig.12.
4.10.3.
After resetting the display shows zero value on Resettable Batch TOTAL, see fig.14.
fig.13
4.10.4.
After a few moments the reset totAl is replaced by totAl.
4.11.
Resetting the Reset Total
4.11.1.
the reset totAl can be reset by pressing the reset key at with a long press, while the display screen shows reset totAl.
follow this procedure:
4.11.1.1. Wait until the display shows TOTAL only , see fig.15.
fig.15
4.11.1.2. Press the reset key. the display screen again shows all the segments of the display followed by all segments of the display turned
off, see fig.16.
4.11.1.3. When the display page is showing the reset totAl is shown, press and hold the reset key again until the resettable totAl turns to
zero, see fig.17 and fig.18.
4.11.1.4. finally the page with the new Reset TOTAL is displayed, see fig.19.
4.12.
Calibration
4.12.1.
in standby mode press and hold the cAl key to see the current calibration factor.
Factory K Factor: Factory-set default factor. It is equal to 1 (indicated as 1,000).
User K Factor: Customised calibration factor, mening modified by calibration.
4.12.2.
the meter has been calibrated at the factory under the following operating conditions:
Fluid: Diesel fuel
Temperature: 20°C (68°C)
Flow Rate: 10-120 litres/min
4.12.3.
calibration is neede to make the meter suitable for actual conditions.
Note: Calibration must be carried out if there is a change in any of the above operating conditions.
© Jack sealey limited
fig.17
fig.19
Original Language Version
fig.12
fig.14
fig.16
fig.18
tP101.V2 | issue:1 30/11/17