Major components
4.2.
4.3.
LCD display
1
resettable Batch totAl (5 digits with moving comma):
indicates volume dispensed after reset button was last pressed.
2
indication of battery charge.
3
indication of calibration mode.
4
Totalizer (6 figures with moving comma in multiples of 10 &100):
indicates two types of totAl:
• Non-Resettable TOTAL (TOTAL)
• Resettable TOTAL (Reset TOTAL)
5
indication of totAl multiplication factor (x10 or x100 ).
6
indication of type of totAl, (totAl / reset totAl).
7
indication of unit of measurement of totAliZer:
l=litres
Gal=Gallons
8
indication of unit of measurement of resettable batch
totAl:
Qts=quarts
Pts=pints
l=litres
Gal=gallons
4.4.
Functions see fig.2
4.4.1.
user Buttons: the meter features two buttons (reset and cAl) which individually perform two main functions and together perform
other secondary functions.
RESET key: is used to reset the Batch totAl and reset totAl.
4.4.1.1.
4.4.1.2.
CAL key: is used to enter the calibration mode.
Combination of RESET + CAL keys: is used to change the unit of measurement and other secondary functions.
4.4.1.3.
4.4.2.
Turbine Assembly: it has two threaded ports: 1 male and 1 female. it contains a turbine which turns when the media passes through it
at sufficient pressure. This action generates electrical pulses which are processed by a microprocessor and the result is displayed on
the lcd.
© Jack sealey limited
fig.3
fig.2
Original Language Version
1
meter label
2
screws
3
display with microprocessor
4
rubber shroud
5
card housing
6
turbine assembly
7
Batteries
8
Battery case
9
Battery cap
10
screws