OPERATION
1. Remove the nut securing the neutral ground wire and
attach the bonded jumper wire. Reinstall the nut.
2. Reinstall the alternator cover.
IMPORTANT: Apply a new "NEUTRAL UNBONDED"
Label over the "NEUTRAL BONDED TO
FRAME" label on the front of the control
panel.

HIGH ALTITUDE OPERATION

Engine power is reduced the higher you operate above sea
level. Output will be reduced approximately 3.5% for every
1000 feet of increased altitude from sea level.
High altitude adjustment is required for operation at
altitudes over 2,000 ft. (762 m). Operation without this
adjustment will cause decreased performance, increased
fuel consumption, and increased emissions.
DO NOT operate the generator at altitudes below 2,000
ft. (762 m) with the high altitude kit installed. Engine
damage may occur.
High Altitude Carburetor Kit Part# 518077
High Altitude DF Regulator: Part# 518050-01
Note: You must purchase both the Dual Fuel Regulator
and Carburetor Kit for proper high altitude operation.

REMOTE START

Verify that the area around the generator is clear before
remote starting the generator.
The remote start key fob included with the generator should
be attached to the recoil handle or control panel. If your
unit was shipped without a key fob, contact Westinghouse
customer service.
The generator can be started remotely from up to 99 feet
(30 meter) using the remote start key fob.
18 | Westinghouse Outdoor Power Equipment, LLC
Neutral ground wire
Bonded jumper wire
NOTICE
WARNING
Note: As the batteries in the remote start key fob drain,
operational distance will decrease.
Note: Remote start-equipped generators must be restarted
with the START/STOP button on the control panel
after an automatic shut-down occurs.
PAIRING THE REMOTE START
Remote replacement batteries: (2) CR2016
Replacement remote: Part# 100714A
If the remote start key fob is replaced or needs re-paired to
the generator, follow this procedure.
1. Turn the generator battery switch to the ON position.
The power indicator light will illuminate.
2. Push and hold the red Pairing button on the side of the
control panel until the START/STOP button illuminates.
Pairing button
3. Push and hold the STOP button on the key fob until the
START/STOP button illumination turns OFF. Release
the button. The START/STOP button will illuminate after
the button is released.
START
STOP
4. Push and hold the START button on the key fob until the
START/STOP button illumination turns OFF. Release
the button. The START/STOP button will illuminate after
the button is released.
5. Push the Pairing button on the side of the control panel
until the START/STOP button illumination turns OFF.
Release the button.