INSTALLATION

For free-standing use: attach the feet to the underneath of
the heater using the four 12mm (½") screws. The feet fit over
the second and third slots from the end of the case.
To wall-mount: Referring to the diagram opposite, draw two
horizontal lines on the wall 330mm (13") apart, the lower line
more than 50mm (2") from the floor.
On the upper line, drill holes 155mm (6·1") from the centre
line, using a 6mm (¼") masonry bit, and insert a wall plug.
On the lower line, drill holes 218mm (8½") from the centre
line using a 6mm (¼") masonry bit, and insert a wall-plug.
Fix the two hook-brackets to the upper holes using the 30mm
(1¼") screws.
Fix the two L-shaped brackets to the underside of the heater
using the 12mm (½") screws through the round hole in the
bracket - the oval hole in the bracket locates over the screw
that fixes the case together,
Hang the heater on the hook-brackets using the two 25mm
(1") slots.
The L-shaped brackets will now line up with the lower holes
in the wall. Attach to the wall using the other two 30mm (1¼")
screws.