TROUBLE-SHOOTING
Fault condition 5
The end sleeve is not separated from band.
Open the cover and disconnect the
mc 25 from mains supply!
If the cutter (1) is damaged or broken off, the cable
crimped with the end sleeve will not be separated
from the band.
In this case remove the tool insert (see also
chapter retooling) and check the cutter (1). When
the cutter (1) is defective, the end-sleeve locator
(3) must be removed by unscrewing the cross-
head screw (2) and a new locator for the corre-
sponding cross section must be fitted.
The corresponding article number is stated in
chapter spare parts.
Fault condition 6
Counter respectively mc 25 do not work.
1. Check mains connection
Check that the mains cable is connected with the appropriate connectors to the mc 25 and the
mains supply. Make sure that you have supply to the plug socket is properly.
2. Check mains fuses
Mains connection must be opened,
disconnect the mc 25 from mains!
 Pull out mains plug (1).
 Pull out the fuse holder (2).
 Check the mains fuses (3).
 Replace defective mains fuses. The corre-
sponding article number is stated in chapter
spare parts.
 Put the mains fuses into fuse holder.
 Insert the fuse holder.
!
Fuse holder must click into place.