Switch Settings For Master In Multiple-Column System; Switch Settings For Slaves In Multiple-Column System - Nortel Meridian 1 Manual

System installation procedures
Table of Contents

Advertisement

Page 92 of 500
Configuring the system monitor
553-3001-210 Standard 14.00 June 1999
For a multiple-column system, set the system monitor in the column
with CPU 0 as the master, using the settings shown in Tables 6 and 8.
Set option switches on slave system monitors as shown in Tables 7 and 9.
If CPU 0 and CPU 1 are in different columns, set the system monitor in
the column with CPU 1 as slave unit 1. Number the slaves sequentially
wherever possible.
Table 6

Switch settings for master in multiple-column system

Switch
1
SW1
off
SW2
on
SW3
on
Set to on for a DC-powered system; set to off for an AC-powered system.
*
**
Set to off if the system is not equipped with a PFTU.
Table 7

Switch settings for slaves in multiple-column system

Switch
1
SW1
off
SW2
off
SW3
off
*
Set to on for a DC-powered system; set to off for an AC-powered system.
Set to on to enable PFTU (if equipped) during over-temperature condition.
**
Set to off to disable PFTU during over-temperature condition.
2
3
4
off
*
on**
off
To set positions 3–8, see Table 8
on
on
on
2
3
4
off
*
**
off
To set positions 3–8, see Table 9
off
off
off
5
6
7
off
off
off
5
6
7
off
off
off
8
off
8
off