Page 68 of 190
Clearing common equipment faults
Symptom:

Call processing stopped (options 61 and 71)

Call processing has stopped on a dual CPU system. Look up all system
messages and maintenance display codes in the X11 system messages guide
and follow the instructions given. If the fault does not clear, use this
procedure. Before you begin:
— Make sure the normal/maintenance switch on both QPC580 CPU
— Take any action indicated by the maintenance display codes.
For information on switch settings, see Circuit card installation and testing
(553-3001-211). Replace equipment as described in Meridian 1 hardware
replacement (553-3001-520). You may need to replace one of the following:
— BTU: QPC477
— CMA card: QPC581 or NTND10
— FN card: QPC579
— IF card: QPC580
— Data cartridge: QMM42
— FDI, MSI or EMSI card: QPC742, QPC584, NT9D34
— FDU or MDU: NT8D68 or NTND15, NT8D69 or NTND16
— Memory card: QPC583 or NTND09
— ROM card: QPC939 or NTND08
— SBE card: QPC215 (option 71)
— 3PE card: QPC441
— CPU/network or CPU card cage: NT6D3903, NT8D3403
553-3001-510 Standard 11.00 June 1999
Interface Cards is set to Norm.
Note: Continually observe and look up codes and system messages as
you perform this procedure.