Before carrying out any maintenance operation o n
your appliance, ensure that it is switched off.

1.3 Overview of your radiator

This electrical appliance with circulating fluid is delivered ready to use.
It is plugged and filled with a high-performance thermal mineral oil before
leaving the factory.
This fluid was specially designed for this use and requires no special
maintenance.
As soon as the appliance is switched on, you will notice certain differences
compared to a standard electric heating system:
- the electric heating element heats the fluid, which gradually and naturally
starts circulating in your appliance;
- the properties of the fluid are such that it takes approximately ten minutes for
the radiator to reach its optimum surface temperature, depending on the model
and the room temperature when the appliance is switched on;
- this principle also ensures consistent and sustained heating even when the
element is no longer powered.
20

2. Installing your appliance

2.1 Warnings

The flexible cable supplied with your appliance is desig-
ned to be connected to the mains via a junction box that must
be placed behind the appliance, with no need for a plug.
In a kitchen or bathroom, the junction box must be
positioned at least 25 cm from the floor.
The appliance must be installed as described in this
document and in accordance with the applicable European
and French standards, including CEI 60364.7.701 and NF
C15-100, as well as the rules of good professional practice.
For other countries (apart from France), the appliance
must be installed in accordance with standards in force and
with rules of good professional practice in the country of use.
IMPORTANT The example shown only concerns a
bathtub. For other bathroom fixtures, please consult
your installer.
IMPORTANT The system must be fitted with an omni-
polar circuit-breaker with a minimum contact opening of
3mm.
Z23370-02
Z23370-02
EN
21