Horizontally Through Wall; Vertically With New Chimney System - Golden Eagle 5040 Owner’s Instruction And Operation Manual

Hide thumbs Also See for 5040:
Table of Contents

Advertisement

INSTALLATION
bolts provided in the kit into the four holes under the stove
at each corner, thread on nuts from the top and tighten.
Make sure to save the hole plugs. NOTE: If converting
from legs to pedestal the hole plugs must be installed in
the unused holes.

HORIZONTALLY THROUGH WALL

WALL
THIMBLE
PL-VENT
ADAPTER
TO
APPLIANCE
1.
Position stove, adhering to clearances shown.
2. Locate position of hole in wall; directly behind stove
exhaust vent.
3. Always maintain 3" clearance from combustible
materials.
4. Install
PL-Vent
wall
manufacturer's instructions.
5. Attach enough piping to penetrate and extend at least
6" beyond exterior walls. An 8-foot vertical pipe run
is suggested where possible to reduce the possibility
of smoke spillage in the event of a loss of negative
pressure.
6. Attach cap and seal outside wall thimbles with non-
hardening waterproof mastic.
FIGURE 8
VERTICAL ROOF VENT
WALL STRAP
SEE VENT MANUFACTURER
FOR NUMBER AND SPACING
6" (153 mm) MINIMUM
CLEARANCE TO ANY
COMBUSTIBLE SURFACE
CLEAN-OUT TEE
A 90 DEGREE ELBOW
MAY ALSO BE USED
6" (153 mm)
MINIMUM CLEARANCE
thimble
per
PL-Vent
7. Termination should not be located so that hot
exhaust gases can ignite trees, shrubs, or grasses
or be a hazard to children. Exhaust gases can reach
temperatures of 500ºF and cause serious burns if
touched.
Locate terminations: a) not less than 3 feet above any
forced air inlet located within 10 feet; b) not less than 4
feet below or horizontally from, or one foot above, any
door, window or gravity air inlet into any building; c) not
less than two feet from an adjacent building and not less
than 7 feet above grade when located adjacent to a public
walkway. Mobile home installations must use a spark
arrester.
VERTICALLY WITH NEW CHIMNEY
SYSTEM
12" MIN
CLEARANCE
TO ROOF
3" MINUMUM
CLEARANCES TO
COMBUSTIBLES
TO
APPLIANCE
OPTION: To achieve a center vertical installation a 45º
elbow and a clean-out tee can be used to offset the pipe
from the exhaust outlet to the rear center of the stove.
OPTION: Install PL-Vent elbow in place of clean-out tee.
Locate stove. Drop plumb bob to center of tee outlet,
mark point on ceiling. Install ceiling support and PL-Vent
pipe per PL-Vent manufacturer's instructions.
1.
Always maintain 3" clearance from combustible
materials. When passing through additional floors or
ceilings, always install firestop spacer.
2. After lining up for hole in roof, cut either a round
or square hole in roof, always 3" larger all the way
around pipe. Install upper edge and sides of flashing
7
© 2021 United States Stove Company
VERTICAL
ROOF VENT
ATTIC
INSULATION
SHIELD
3" MINUMUM
CLEARANCES TO
COMBUSTIBLES
CLEANOUT
TEE
45° ELBOW