Golden Eagle 5040 Owner’s Instruction And Operation Manual page 11

Hide thumbs Also See for 5040:
Table of Contents

Advertisement

OPERATION
HEAT LEVEL ADVANCE
• This button when pushed will set the pellet feed rate,
hence the heat output of your stove. The levels of heat
output will incrementally change on the bar graph
starting from level "1" to "4".
NOTE: When dropping more than 2 heat level settings (i.e.
4 to 1) push the 'High Fan' button and allow the room air
fan to run at that setting for at least 5 minutes to prevent
the stove from tripping the high temp thermodisc. If the
high temp thermodisc does trip (see "Safety Features"
section of this manual).
CAUTION:
THE "4" SETTING IS DESIGNED FOR TEMPORARY
USE ONLY. IF USED FOR EXTENDED PERIODS,
IT CAN SHORTEN THE LIFE EXPECTANCY OF
THE UNITS COMPONENTS. AVOID USE AT THIS
SETTING FOR MORE THAN ONE HOUR AT A TIME.
OPTIONAL THERMOSTAT
An optional thermostat may help you maintain a constant
house temperature automatically. A millivolt thermostat
is required. The control panel can be set up two ways to
On/Off High/Low Manual
operate your stove in thermostat mode.
On/Off High/Low Manual
Connect
Thermostat
Wires Here
N
FIGURE 14
THERMOSTAT INSTALLATION
• A MILLIVOLT THERMOSTAT IS REQUIRED.
• Unplug stove from power outlet.
• Remove control board from stove.
• The two thermostat wires connect to the terminal block
on the lower left side of the back of the control board.
• Insert wires in the terminal side and tighten the two
screws.
MODES
TO SWITCH BETWEEN ANY OF THE THREE MODES,
THE STOVE MUST BE SHUT OFF, THE NEW MODE
SELECTED AND THE STOVE RESTARTED.
MANUAL MODE
• USE THIS MODE EXCLUSIVELY IF YOU DO NOT
CONNECT AN OPTIONAL THERMOSTAT.
• In this mode, the stove will operate only from the
control panel as detailed in the "Operation" section of
this owner's manual.
HIGH/LOW THERMOSTAT MODE
• USE THIS MODE ONLY IF YOU CONNECT A
THERMOSTAT.
• When engaged in this mode, the stove will automatically
switch be- tween two settings. When warm enough, it
will switch to the #1 or low setting. The room air blower
will also slow to its lowest speed.
• The Heat Level Advance setting on the bar graph will
stay where it was initially set. When the home cools
below the thermostat setting, the stove will switch to
the feed rate of the heat level advance setting.
ON/OFF THERMOSTAT MODE
• USE THIS MODE ONLY OF YOU CONNECT A
THERMOSTAT
• In this mode, when the home is warm enough, the stove
will shut off. The fans will continue to run until the
stove cools.
• When the home cools below the thermostat setting,
the stove will automatically restart and run at the last
feed rate setting.
NOTE: When in "High/Low" or "On/Off" thermostat mode
• Do not operate the stove higher than the #3 setting.
• Set damper control rod approximately 1/4" (7 mm) to
1/2" (13 mm) out. This will vary depending on elevation
and weather conditions. Observe stoves operation and
adjust damper as necessary.
11
© 2021 United States Stove Company

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Golden Eagle 5040

Table of Contents