INSTALLATION
PREPARATION
Factory packaging must be removed, and some minor
assembly work is required prior to installation. Access
to the rear of the stove is necessary. The circuit board/
control panel must be unpacked and installed in the side
flashing on the insert or side panel on the freestanding.
See installation instructions provided with the circuit
board. NOTE: Normally, your dealer will perform these
functions.
FLOOR PROTECTION
Freestanding installations-The stove must be placed on
a continuous (grouted joints) noncombustible material
such as ceramic tile, cement board, brick, 3/8" millboard
or equivalent, or other approved or listed material
suited for floor protection. THE MATERIAL(S) USED
MUST HAVE, OR COMBINE TO HAVE, A MINIMUM
INSULATION RATING OF 'R1'.
2"
NOTE: ceramic tile, or any tile, requires a continuous
sheet beneath to prevent the possibility of embers falling
through to the combustible floor if cracks or separation
should occur in the finished surface, this would include
floor protection for Built-in raised hearths. Check
local codes for approved alternatives. Clearances are
measured from the sides, back and face (door opening)
or stove body. DO NOT USE MAKESHIFT MATERIALS
OR COMPROMISES IN THE INSTALLATION OF THIS
UNIT. INSTALL VENT WITH CLEARANCES SPECIFIED
BY THE VENT MANUFACTURER. CAUTION: DO NOT
CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR
DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY
APPROVED FOR SUCH INSTALLATIONS.
CLEARANCES
This unit has been tested and listed for installation in
residential, mobile home and alcove applications.
2"
28"
6"
WITH
VERTICAL
*
1"
EXHAUST
8 1/4"
(TOP)
9"
(SIDEWALL)
48" MIN.
*
WITH HORIZONTAL EXHAUST
WITH
VERTICAL
EXHAUST
8 1/4"
(TOP)
9"
(SIDEWALL)
STOVE DOOR FACE MUST BE EQUAL TO OR
PROTRUDE OUT FROM FACE OF ALCOVE.

ALCOVE CLEARANCES

COMBUSTION AIR SUPPLY
DO NOT VENT UNDER ANY PORCH, DECK,
AWNING, OR IN ANY SEMI ENCLOSED OR
ROOFED AREA. DOING SO MAY RESULT IN
UNPREDICTABLE AIRFLOW AT THE VENT CAP
UNDER CERTAIN CONDITIONS AND CAN AFFECT
THE PERFORMANCE OF YOUR STOVE, AS WELL
AS, OTHER UNFORESEEABLE ISSUES.
If outdoor combustion air is supplied the heater must be
attached to the structure. For a mobile home installation
the stove must be connected to an outside source of
combustion air. A 2" inside diameter metallic pipe, either
5
© 2021 United States Stove Company
1"
3"
36" MAX.
38" MIN.
BACKWALL
3"
1"
*
8 1/4"
(TOP)
9"
(SIDEWALL)
ATTENTION:
3"
3"
1"