Maico ECA piano Installation And Operating Instructions Manual

Maico ECA piano Installation And Operating Instructions Manual

Hide thumbs Also See for ECA piano:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Montage- und Betriebsanleitung
Installation and operating instructions
Notice de montage et mode d'emploi
Kleinraumventilatoren
Small room fans
Aérateurs pour petites pièces
ECA piano
STANDARD
ECA piano TC
ECA piano H

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECA piano and is the answer not in the manual?

Questions and answers

Summary of Contents for Maico ECA piano

  • Page 1 Montage- und Betriebsanleitung Installation and operating instructions Notice de montage et mode d'emploi ECA piano STANDARD ECA piano TC ECA piano H Kleinraumventilatoren Small room fans Aérateurs pour petites pièces...
  • Page 2 Inhaltsverzeichnis Deutsch......... English .......... Français ........
  • Page 3 Geräteübersicht Geräteübersicht Gehäuse mit Motor Platinenträger Klemmleiste ECA piano STANDARD Timerplatine ECA piano TC Feuchteplatine ECA piano H Motordeckel Abdeckung Dichtring Klappe Flügelrad mit Ringfeder...
  • Page 4: Table Of Contents

    Qualifikation Fachinstallateur ..... Bestimmungsgemäße Verwendung ..Sicherheitshinweise ......Allgemeine Sicherheitshinweise Sicherheitshinweise zu Installa- tion, Betrieb, Reinigung und Wartung ........Produktinformationen ......ECA piano ......... ECA piano TC......ECA piano H......Technische Daten ......... Umgebungsbedingungen ..Technische Datentabelle ... Montagevorbereitungen ....... Wand .........
  • Page 5: Lieferumfang

    Brand geraten können. • Ventilator GEFAHR Explosionsfähige Gase und • Dichtring Stäube können entzündet werden und zu • Schaumstoffband (nur ECA piano H) schweren Explosionen oder Brand führen. • Montage- und Betriebsanleitung Ventilator auf keinen Fall in explosionsfähiger At- mosphäre einsetzen (Explosionsgefahr).
  • Page 6: Produktinformationen

    4 Pa. Die Ausführung bedarf 5 Produktinformationen grundsätzlich der Zustimmung des Bezirks- schornsteinfegers. 5.1 ECA piano Bei Betrieb mit raumluftabhängiger Feuerstätte • Kleinraumventilator zum Entlüften von Räumen. unbedingt für eine ausreichende Zuluftnachströ- mung sorgen. • Standardausführung. • ECA piano mit feststehendem Innengitter.
  • Page 7: Eca Piano Tc

    • Kleinraumventilator zum Entlüften von Räumen. 6 Technische Daten • Ausführung mit einstellbarer Nachlaufzeit. • ECA piano TC mit feststehendem Innengitter. 6.1 Umgebungsbedingungen • Nachlauf einstellbar von 3 bis 25 Minuten • Zulässige Höchsttemperatur des Fördermedi- (Werkseinstellung 6 Minuten).
  • Page 8: Decke

    1. Montagevorbereitung wie in Kapitel Wand be- schrieben, vornehmen. 1. Gehäuserückseite auf vorhandenen Dichtring und dessen festen Sitz überprüfen. 2. ECA piano STANDARD, ECA piano TC: Ggf. Hilfsmittel (z. B. Schaumstoffband) zum Fixie- ren in Wand oder Rohr anbringen. Dabei Min- destabstand 20 mm zum Stutzenende einhal- ten! Lagerung der Klappen nicht überkleben...
  • Page 9: Montage Und Inbetriebnahme

    (beide bauseitig). Ventilator schaltet aus, wenn nach Betätigen des Schalters die Nachlauf- zeit abgelaufen ist. Nachlaufzeit ca. 3...25 Min., ab Werk: ca. 6 Min. ECA piano H mit Feuchtesteuerung und ein- stellbarer Nachlaufzeit Funktion je nach Anschlussvariante unterschied- lich. 2. Netzleitung an der Klemmenleiste anschließen Variante 1: Ventilator schaltet automatisch ein, →...
  • Page 10: Wartung

    Abdeckungen fachkräfte zulässig. ABD ECA piano 1 E059.1125.9000 ABD ECA piano 2 E059.1125.9100 Leiterplatten PL ABDE ECA piano E101.1403.0001 PL ABDE ECA piano H E101.1402.0002 Kondensator KS RCA ER E157.0116.0000 Bei Rückfragen Maico Elektroapparate-Fabrik GmbH Steinbeisstraße 20 78056 Villingen-Schwenningen, Deutschland...
  • Page 11: Demontage

    Schraubendreher aus Rasterung drücken. 3. Motordeckel abnehmen. Impressum 15 Umweltgerechte Entsorgung © Maico Elektroapparate-Fabrik GmbH. Deutsche Original-Betriebsanleitung. Druckfehler, Irrtümer Das Gerät und auch die Verpackung enthalten und technische Änderungen vorbehalten. Die in wiederverwertbare Stoffe, die nicht in den Rest- diesem Dokument erwähnten Marken, Handels-...
  • Page 12 Unit overview Unit overview Housing with motor Circuit board holder Terminal block ECA piano STANDARD Timer circuit board ECA piano TC Humidity circuit board ECA piano H Motor cover Cover Gasket Shutter Impeller with annular spring...
  • Page 13 Safety instructions ........ General safety instructions ..Safety instructions regarding in- stallation, operation, cleaning and maintenance ......Product information ......ECA piano ........ECA piano TC......ECA piano H....... Technical data ........Ambient conditions ..... Technical data table ....Preparation for installation ....
  • Page 14: Scope Of Delivery

    DANGER Explosive gases and dust may ignite and cause serious explosions or fire. • Gasket Never use fan unit in an explosive atmosphere • Foam strip (only ECA piano H) (risk of explosion). • Installation and operating instructions WARNING Risk from operating in single...
  • Page 15: Product Information

    • Small room fans for extracting air from rooms. Only operate the fan when it is completely in- • Model with adjustable overrun time. stalled. • ECA piano TC with fixed internal grille. Do not commission a damaged unit.
  • Page 16: Eca Piano H

    V) to zero. The capacitor is to be function) and adjustable overrun time. provided by the customer. • ECA piano H with fixed internal grille. • Storage: Store unit exclusively in a dry location (-20 to +50 °C). • Barrier-free product as the fan switches itself on and off automatically.
  • Page 17: Ceiling

    7.5 Preparations for operation with speed controller Only for ECA piano STANDARD. 2. Prepare cover. Remove the cover before Not permissible for ECA piano TC and H mod- drilling the housing. Drill cover with suitable els. drill to avoid moisture and the formation of bacteria in the fan housing.
  • Page 18: Electrical Connection

    2. Connect power cable to terminal block → Wir- ing diagrams [} 20]. 8.4 Commissioning 3. ECA piano TC and H: Perform potentiometer 1. Check the shutters for ease of movement and settings → Position P in the Unit overview intactness.
  • Page 19: Maintenance

    Repairs should only Printed circuit boards be carried out by a qualified electrician. PL ABDE ECA piano E101.1403.0001 PL ABDE ECA piano H E101.1402.0002 Capacitor KS RCA ER E157.0116.0000 In case of questions, please contact: Maico Elektroapparate-Fabrik GmbH Steinbeisstraße 20...
  • Page 20: Dismantling

    14 Dismantling Spare parts can be ordered at www.shop.maico- ventilatoren.com. 14 Dismantling Dismantling only permitted by a qualified elec- ECA piano TC trician. 14.1 Removing cover, locking hook, motor cover ECA piano H Motor cover 1. First pull off the lower third of the cover, then remove it.
  • Page 21 Vue d'ensemble de l'appareil Vue d'ensemble de l'appareil Boîtier avec moteur Porte-platine Réglette de bornier ECA piano STAN- DARD Platine minuterie ECA piano TC Platine humidité ECA piano H Couvercle du moteur Cache de protection Joint d'étanchéité Volet Hélice avec anneau-resort...
  • Page 22 Sommaire Sommaire Volume de fourniture......23 Qualification de l'installateur spécia- lisé ............Utilisation conforme ......23 Consignes de sécurité ......23 Consignes de sécurité géné- rales........... Consignes de sécurité pour l'installation, le fonctionnement, le nettoyage et l'entretien... Informations produit......25 ECA piano .........
  • Page 23: Volume De Fourniture

    Avant-propos Avant-propos DANGER Risque d'inflammation / d'incen- Veuillez lire attentivement cette notice avant le die résultant de la présence de matériaux, li- montage et la première utilisation. Suivez les ins- quides ou gaz combustibles à proximité de tructions. Remettez les notices au propriétaire l'appareil.
  • Page 24: Consignes De Sécurité Pour

    4 Consignes de sécurité 4.2 Consignes de sécurité pour l'ins- AVERTISSEMENT Risque de blessure tallation, le fonctionnement, le net- lors des travaux en hauteur. Utiliser des auxiliaires d'accès vertical (échelles) toyage et l'entretien appropriés. Assurer la stabilité. Le cas échéant, faire appel à DANGER Danger pour les enfants et les une 2ème personne pour maintenir l'échelle.
  • Page 25: Informations Produit

    5 Informations produit 5.2 ECA piano TC DANGER Danger en cas de non-respect • Aérateur pour petite pièce destiné à l'évacua- des consignes en vigueur relatives aux instal- tion d'air des locaux. lations électriques. Avant toute installation électrique, couper tous • Version avec durée de fonctionnement par tem- les circuits d'alimentation électrique, mettre le fu- porisation réglable.
  • Page 26: Caractéristiques Techniques

    Tension de service 230 V CA Fréquence du secteur 50 / 60 Hz Niveau de pression 26 dB(A) acoustique Type de protection IP X4 Poids 0,5 kg Pour des caractéristiques techniques supplémen- taires → plaque signalétique. Pour courbes caractéristiques → www.maico- ventilatoren.com.
  • Page 27: Gaine Ronde

    1. Enlever les volets. teur. 2. Utiliser le régulateur de vitesse STX de la ATTENTION Risque de court-circuit et d'en- gamme d'accessoires Maico. dommagement de l'appareil résultant de la formation de condensat dans le boîtier du ATTENTION Arrêt et dysfonctionnement du ventilateur.
  • Page 28: Branchement Électrique

    9 Utilisation 8.2 Branchement électrique 8.3 Montage final 1. Presser uniformément le couvercle du moteur ATTENTION Endommagement de l'appareil en cas de court-circuit. sur le ventilateur → Vue d'ensemble [} 21]. Isoler le conducteur de protection et les conduc- Appuyer fermement le couvercle du moteur, teurs non utilisés.
  • Page 29: Entretien

    10 Entretien du ventilateur est inférieure au point de commuta- Dysfonctionnement Cause, mesures tion et que la durée de fonctionnement par tem- Le ventilateur ne se Pas de tension du sec- porisation est expirée. met pas en marche. teur. Contrôler si le fu- sible secteur fonctionne 10 Entretien correctement.
  • Page 30: 14 Démontage

    E101.1403.0001 no TC PL ABDE ECA piano H E101.1402.0002 Condensateur KS RCA ER E157.0116.0000 Adressez vos questions à : Maico Elektroapparate-Fabrik GmbH Steinbeisstraße 20 78056 Villingen-Schwenningen, Allemagne Tél. +49 7720 694 445 Fax +49 7720 694 175 E-mail : ersatzteilservice@maico.de Couvercle du moteur 1. Retirer d'abord le cache de protection dans le Les pièces de rechange peuvent être comman-...
  • Page 31 Mentions légales ECA piano H Variante 1 Variante 2 Mentions légales © Maico Elektroapparate-Fabrik GmbH. Traduc- tion du mode d'emploi d'origine en langue alle- mande. Sous réserve de fautes d'impression, d'erreurs et de modifications techniques. Les marques, marques commerciales et marques dé- posées, dont il est fait mention dans ce document...
  • Page 32 Maico Elektroapparate-Fabrik GmbH Steinbeisstr. 20 78056 Villingen-Schwenningen Deutschland Service +49 7720 6940 info@maico.de 0185.1111.0005_RLF.8_04.21_DSW-AS...

This manual is also suitable for:

Eca piano tcEca piano h

Table of Contents