6. ANHÄNGE
6.1 Stromlaufpläne
COMP
CC
CR
BLK
CS
RED
WHT
C1
L
N
RED BLU
L
N
1
2
230V / 50Hz
Versorgung
Potentialfreier
Trockenkontakt
7 A max.
HINWEISE:
AT : SENSOR FÜR DIE LUFTTEMPERATUR
COMP : KOMPRESSOR
CT : SENSOR FÜR DIE VERDUNSTERTEMPERATUR
FM : VENTILATORMOTOR
FS : SENSOR FÜR VORHANDENES WASSER
HP : DRUCKREGLER HOCHDRUCK
IT : SENSOR FÜR DIE TEMPERATUR DES EINGANGS-
1
N
2
C2
BLK
BLU
FM
RED
4V
OUT3
OUT4
OUT5
AC-N
2
2
TC
Controller
12V
3
5
7
01
4
6
8
OUT1
OUT2
FS
LP
HP
WASSERS
LP : DRUCKREGLER FÜR NIEDERDRUCK
OT : SENSOR FÜR DIE TEMPERATUR AM WASSER-
AUSGANG
TC : TRANSFORMATOR 230V / 12V
C1 : KOMPRESSOR-KONDENSATOR
C2 : VENTILATOR-KONDENSATOR
HPR06M
GND
AI06
5K
AT
GND
t
AT
AI05
5K
CT
GND
t
CT
AI04
5K
OT
GND
t
OT
AI03
5K
IT
GND
t
IT
AI02
6.8K
GND
AI01
+5V
GND
15