Operating Conditions - IMAGO VisionCam XM Hardware Manual

Hide thumbs Also See for VisionCam XM:
Table of Contents

Advertisement

2 Introduction

Operating Conditions

Power Supply:
Parameter
Supply Voltage
Supply Voltage for use with internal ring light
2
Supply Current
(@24V)
RS-232:
Parameter
Signal Input Range
Output Voltage Swing, all Outputs Loaded with 3 kΩ
to GND
Data Rate, R
= 3kOhm, C
L
Digital Input:
Parameter
Input Voltage
High Level Current Threshold
Maximum Current Internal Limited
Threshold Voltage
Signal Frequency
Digital Output:
Parameter
Common VCC Supply Voltage
Output Current, Saturated Operation (V
Turn-On Time (24 V Common VCC, 10 mA)
Turn-Off Time (24 V Common VCC, 10 mA)
Flash (Strobe) Unit:
Parameter
Maximum Strobe Current
Strobe Current Step Size
Minimum Flash Duration @ 2A
Flash Duration Step Size
Maximum Flash Duration is Limited to ~ 0.8W Power
Dissipation Inside the Flash Unit
2
Actual current draw depends on hardware configuration and CPU/system load
Strassheimer Str. 45; 61169 Friedberg; Germany; Tel. +49(0)6031-6842611; Fax +49(0)6031-6842612
= 1000 pF
L
CE
IMAGO Technologies GmbH
info@imago-technologies.com; www.imago-technologies.com
Min
11
Min
– 25
 5
1200
Min.
6
6
Min.
< 1 V)
10
Min
Page 8 / 44
Typ.
Max
Unit
26.4
V
24
V
0.25
A
Typ.
Max
Unit
25
V
 5.4
V
115200 bps
Typ.
Max.
Unit
24
30
V
1
5
mA
21
mA
11
V
5
MHz
Typ.
Max.
Unit
30
V
20
mA
5
µs
15
µs
Typ.
Max
Unit
2
A
10
mA
10
µs
1
µs