3 Interfaces

Digital I/O

The digital I/O interface provides two opto-isolated inputs and four opto-isolated outputs.
The input group is electrically isolated from the output group. Both groups are also isolated
from other VisionCam circuits and interfaces.
The following illustration shows the corresponding electrical equivalent circuit:
VisionCam
Galvanic isolation
IN 0
Current
Limit
IN 1
Current
Limit
GND
The input group requires external connection of a shared GND reference.
For the output group, the user must provide a shared supply voltage to the VCC pin. See
chapter 3.1 for the connector pinout.
Strassheimer Str. 45; 61169 Friedberg; Germany; Tel. +49(0)6031-6842611; Fax +49(0)6031-6842612
Communication
Figure 2: Simplified digital I/O circuit
IMAGO Technologies GmbH
info@imago-technologies.com; www.imago-technologies.com
Real-Time
Controller
(FPGA)
Page 15 / 44
Galvanic
isolation
VCC
OUT 0
OUT 1
OUT 3