PARTS INCLUDED:
1 - Bracket, Filter Std. Housing w/ screws (P/N 0505639)
1 - Housing, Bowl, and Head (P/N 2180258)
1 - Wrench, Filter (P/N 2180244)
1 - Tee 3/4" NPT (P/N 2190184)
1 - Nipple, Hex 3/4" NPT x 1-1/2" LG (P/N 2070117)
1 - TAC-01 Cartridge (P/N 7000708)
1 - Instruction Sheet (P/N 1011013)
TOOLS:
• Mounting Hardware (Not Provided)
• Drill with bits
• Tape Measure
• Pipe Wrenches
• Adjustable Wrenches
• Level
• Pipe Dope, Thread Seal Tape, or Thread Sealing Cord
• Screwdriver (Flat Blade and Phillips)
• Two Gallon Bucket
• Fresh 6% unscented liquid chlorine bleach
General
If you experience any problems with these instructions, or if
any parts are damaged or missing, contact Antunes Technical
Service at +1-877-392-7854 toll free.
The TAC System improves the quality of water by addressing
scale issues on hot water applications. It should be installed
upstream of equipment using hot water.
CAUTION
Do not use this system with water that is microbiologi-
cally unsafe or of unknown quality without adequate dis-
infection installed before or after the system.
Equipment Setup
When installing the system, pay attention to the following guide-
lines:
•
Do not install above electrical equipment.
•
Allow space below the TAC Housing for TAC Cartridge
replacement.
PLUMBING
NOTE: This system is designed to be used on tap water not
to exceed 100°F (38°C) or 100 psig (690 kPa). The kit must
be connected to the COLD water line. Do not connect the
kit to the hot water line.
The TAC System has the following connections:
•
Inlet
3/4" NPT
•
Outlet
3/4" NPT
+1-877-392-7854
ANTUNES www.antunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188
TAC-01 SYSTEM (P/N 9700903)
When making a plumbing connection to the System, use a
back-up wrench on the supporting plumbing. Always use a
quality, approved pipe sealant or thread seal tape on the pipe
threads. Be careful not to get the pipe sealant inside the pipe
when making connections.
DO NOT over tighten the connections. The use of plastic fittings
when connecting to the plastic head will reduce the possibility of
cracking the head due to over tightening.
If soldered plumbing is used, do not apply heat to, or near, the
Head. The use of union (o-ring seal) connections is highly rec-
ommended for ease of installation and future servicing.
This equipment must be installed to comply with the
basic plumbing code of the Building Officials and Code
Administrators, Inc. (BOCA) and the Food Service
Sanitation Manual of the Food and Drug Administration
(FDA).
Water pressure must not exceed 100 psig. To reduce
water pressure, install a water pressure regulator and set
the water pressure to below 100 psig.
Head Bracket
and Screws (8)
Head
O-Ring
(incl. with Head)
Figure 1. TAC-01 System
Page 1 of 2
CAUTION
CAUTION
Filter Wrench
P/N 1011013 Rev. B 05/17
TAC
Cartridge
Housing
Need help?
Do you have a question about the TAC-01 and is the answer not in the manual?
Questions and answers