Mantel And Finishing Requirements

GAS CONVERSION (SOLD SEPARATELY)

CAUTION: The conversion shall be carried out in accordance with the requirements of the provincial authorities
having jurisdiction and in accordance with the requirements of the ANSI Z223.1 installation code.
This appliance is manufactured for use with natural gas. Follow the instructions included with the conversion kit if
converting to LP gas. The conversion kit shall be installed by a qualified service agency.

GAS LINE INSTALLATION

CAUTION: Installation of the gas line must only be done by a qualified person in accordance with local building
codes, if any. If not, follow ANSI 223.1. Commonwealth of Massachusetts installations must be done by a
NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at pressures in excess of 1/2 psi (3.5 kPa). For test pressures equal to
or less than 1/2 psi (3.5 kPa), the appliance must be isolated from the gas supply piping system by closing its
individual manual shut-off valve. A listed (and Commonwealth of Massachusetts approved) 1/2" (13 mm) tee
handle manual shut-off valve and flexible gas connector are to be connected to the 1/2" (13 mm) control valve
inlet. If substituting for these components, please consult local codes for compliance.
• This appliance is equipped with a 3/8" (10 mm) x 18" (457 mm) long flexible gas connector and manual shut-
off valve.
• Run gas line into appliance. The gas line should be run to the point of connection where the shut-off valve and
flexible gas line will connect.
• Do not run gas line in a manner that would obstruct fan operation.
• For high altitude installations, consult the local gas distributor or the authority having jurisdiction for proper
rating methods.
Inlet Gas Supply Pressures
Fuel
Minimum Pressure
Natural Gas
5" WC (1.25 kPa)
LP Gas
11" WC (2.74 kPa)
From Face of Cement Board
Any Mantle Depth
Face of 1/2" thick
non-combustible
cement board
Do not put furniture
or objects within
36" (915 mm) of
the appliance front
Fireplace
Opening
4" minimum to
non-combustible
hearth
9" (230 mm)
Bottom of Unit

Gas Line Connection

licensed plumber or gas fitter.
Maximum Pressure
10" WC (2.49 kPa)
14" WC (3.49 kPa)
Min. 1"
(25.4 mm)
clearance to
combustibles
around
vertical
vent pipe
F
a r
m
n i
g
w
i
h t
P
a
i t r
l a
S
h
e
f l
-11-
17-1/8"
(436 mm)
Approx. 10-3/4" (274 mm)
from back surface of
wall nish to front surface
of appliance case w/no
vent o set
1/2" thick
non-combustible
Cement Board
Fireplace
Opening
T
o
p
O
u
l t
t e