Clean Dirt Interceptor (Only For Water-Cooled Units) - Gardner Denver L Series Original User And Service Manual

Frame 5 base mounted compressor
Hide thumbs Also See for L Series:
Table of Contents

Advertisement

b) Switch cabinet inlet filter (-4- Fig. 23)
(only L90RS-L132RS)
Fig. 24
Fig. 25
Perform filter mat change as follows:
Open the louver grilles of the inlet filter (Fig. 24).
Remove the filter pad.
Insert the new filter pad into the louver grille. Ensure
that the smooth side (-A- Fig. 25) of the filter pad
faces the air inlet side.
Place the louver grille back onto the filter housing.
Changing times for the filter mat
The operating modes and the quality of the suctioned
air (e.g., dust content) has a strong influence on the
filter service life.
The filter should be checked on a weekly basis,
eventually daily basis, for dust build-up.
In these cases the intervals between changes may be
shorter.
10.13 Clean dirt interceptor (only for water-
cooled units)
DANGER
Only perform checks and carry out work on
the screw compressor when the unit is out
of operation, depressurized, and secured
from being switched on again!
Fig. 26
1 Dirt interceptor
2 Cooling water solenoid valve
3 Manual regulating valve
Lock water inflow and water outflow on the compressor.
Provide a suitable container in order to catch any
cooling agents draining from the system.
Carefully loosen the cover of the dirt interceptor. Catch
any cooling agent draining from the system.
Remove cover and pull filter insert from the housing.
Clean filter insert or replace with a new one.
Push filter insert into the dirt interceptor housing.
Screw cover into the housing. Ensure that the seal is
correctly positioned and that there is no dirt on the
sealing ring and the sealing areas.
Tighten cover with a suitable tool.
Check all connections for tightness.
Open water inflow and outflow at the compressor.
13-25-639 v00