Gardner Denver L Series Original User And Service Manual page 33

Frame 5 base mounted compressor
Hide thumbs Also See for L Series:
Table of Contents

Advertisement

Fig. 13
1 Oil filler cap R1"
2 Oil-level indicator
3 Maximum oil level
4 Minimum oil level
Check the oil level as follows:
Shut off the compressor with the STOP button.
Wait at least 5 minutes until the oil has settled, i.e. until the air has bubbled out.
The oil level should be checked at each pause in operation and at regular intervals using the transparent plastic tube
on the pressure reservoir (- 2 - Fig. 13).
The oil level must lie between the "maximum oil level" (- 3 - Fig. 13) and "minimum oil level"
(- 4 - Fig. 13) marks on the oil container.
If required, top up oil. Use Gardner Denver oil only.
Close the oil filler cap (-1- Fig. 13) firmly.
Also see Section 10.15 "Service and Maintenance."
13-25-639 v00