Re-start after an automatic shutdown due to a malfunction as follows:
Faults are shown as text in the compressor controller Alarms menu.
Turn master switch off and secure it from being switched on again.
Eliminate fault.
Turn master switch on.
Acknowledge the fault in the Alarms menu. After the acknowledgement, the message [READY TO START]
appears on the display, unless another fault is present.
Press START button [ I ] (-2- Fig. 15).
8.6

Shutoff

To switch off the compressor use the O (STOP) key (-3- Fig. 15) and not the EMERGENCY STOP button. After
shutdown the compressor has a run on time of 30-50 seconds (soft-stop).
NOTICE
The unit may only be shut down using the emergency stop button in real emergencies. When shutting
down normally, please use the O (STOP) key.
8.7

Emergency stop

The EMERGENCY STOP button is situated next to the compressor controller. It is used to immediately shut down the
unit. Only use the EMERGENCY STOP button (-4- Fig. 15) to shut down the unit in emergencies. When shutting
down normally, always use the [O] (Stop) key.
WARNING
Do not stop the Unit using the Emergency Stop Button unless there is a danger to the product or of personnel injury.
Using the Emergency Stop Button, disconnect, or breaker to stop the Unit will not all the Unit to go through an
unloading sequence, and could result in damage to the Motor, Stater, or other electrical components. Damage
caused in this manner is not covered by the manufacturer's Warranty.
13-25-639 v00