To establish an electrical connection, proceed as
follows:
Route the supply cable through the conduit
(-1 - Fig. 11) on the control cabinet.
Connect the supply line to the connecting terminals as
shown in the circuit diagram.
Variable speed units are supplied with appropriately-
sized crimp-on lugs. These may be utilized to
terminate the supply conductors to the line side of the
VFD. The final installation is up to the discretion of the
installer's certified electrical contractor and local
electrical codes.
Fig. 14

7.4.1 Check setting of the fan protection switch (only for L90RS-L132RS)

Check the setting of the motor protection switch in accordance with the enclosed circuit diagram for the compressor.
Set the protection switch to the value stated in the table corresponding to the mains voltage and frequency (see circuit
diagram).