5.1

Design of the unit

5.1.1 Design of air-cooled units

Fig. 2
1 Intake filter
2 Suction regulator
3 Electric motor
4 Screw compressor
5 Demister vessel
6 Fine oil separator
7 Oil filling
8 Oil draining
9 Oil level indicator
10 Oil filter
11 Oil cooler
12 Pressure relief valve
13 Minimum pressure and
non-return valve
14 Air cooler
15 Fine oil separator extraction
16 Oil temperature regulator
17 Cooling fan
18 Cool air inlet filter pad
19 Compressed air outlet
20 Base frame
21 Compressor controller
22 Emergency stop button
23 Switch cabinet
13-25-639 v00
24 Feed cable entry
25 Final compression temperature
sensor
26 System pressure sensor
27 Final compression pressure
sensor
28 Opening for lifting equipment
29 Fan guard
30 Pressure relief for cooler
31 Heat-recovery connection (option)