Mercado Medic REAL 8100 PLUS Instructions For Use And Care Manual

X-ray medical clinic chairs

Advertisement

Quick Links

INSTRUCTIONS FOR USE
for REAL 8100 PLUS X-ray medical clinic chairs
UK
Instructions for use and care
Translation of manual
Item number: 21-08993-UK
Revision: 00
Valid from: 2021-05-26
Amended: -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the REAL 8100 PLUS and is the answer not in the manual?

Questions and answers

Summary of Contents for Mercado Medic REAL 8100 PLUS

  • Page 1 INSTRUCTIONS FOR USE for REAL 8100 PLUS X-ray medical clinic chairs Instructions for use and care Translation of manual Item number: 21-08993-UK Revision: 00 Valid from: 2021-05-26 Amended: -...
  • Page 2 [Space for device label with serial number]...
  • Page 3: Table Of Contents

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Table of contents User information 5.9. Base ......22 5.10.
  • Page 4: Introduction

    We manufacture all our different medical chairs under our own management in Sweden. Mercado Medic is certified to ISO 13485, ISO 9001 and ISO 14001, and complies with applicable labour and environmental legislation.
  • Page 5: Contact Details

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Introduction 1.1. Contact details 1.2. Warranty Manufacturer All components of Mercado Medic's devices Street address: Mercado Medic AB, are covered by warranty, under the time Tryffelslingan 14, SE-181 57 Lidingö, Sweden...
  • Page 6: Getting Started

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Getting started 2. Getting started This section is primarily aimed at you, the operator of the device. It describes how to prepare it for use, how to use its functions, and how to charge it. For care instructions, see 3. Caring for the device.
  • Page 7 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Getting started Battery Backrest mechanism Brake lever Armrests Figure 2.1. Preparations before the device is put into use. Consider the following before and during • The optional foot support ring is designed use of the device to rest your feet on, not to stand on.
  • Page 8 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Getting started • Never adjust the seat to a height where it Warning! The device may be is unsafe for the patient to get up from the equipped with long cables or device.
  • Page 9: How To Operate The Device Functions

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Getting started 2.2. How to operate the device functions The device is equipped with electric height adjustment controlled by wireless remote control. The device is equipped with electric or manual height adjustment, depending on the model.
  • Page 10: Charging

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Getting started 2.3. Charging How to charge the device 1. Inset the plug into the charging outlet The battery should be charged once every 24 (see Figure 2.4). The charging outlet is hours.
  • Page 11: Caring For The Device

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Caring for the device 3. Caring for the device Clean the device according to the instructions in this section to maintain its functions and service life. If needs arise that cannot be met with the resources available, please contact your distributor for reconditioning.
  • Page 12: Transport And Storage

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Caring for the device 3.4. Transport and storage during transport, the backrest can be removed and the armrests lowered. Be When transporting and storing the device, sure to select the settings so that they keep the following in mind: can be easily reset.
  • Page 13: Intended Use

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs intended use 4. intended use 4.1. Operating environment The REAL 8000 product series comprises modular patient seats designed to be used • The device is intended for indoor use only together with primary clinical examination and must not be used outdoors.
  • Page 14: Configurations And Settings

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Configurations and settings 5. Configurations and settings 5.1. Required level of competence for It describes the device's models, options setting and adjusting when configuring the device, and information about setting and adjusting the device's To attain the best position for correct X-rays, functions.
  • Page 15: Basic Design

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Configurations and settings 5.2. Basic design All devices come with a seat, two types of back support, folding armrests, a base with four castors (standard: 100 mm), brake, seat tilt and lockable seat rotation. The device comes in two models: Standard and Comfort.
  • Page 16: Electrical Functions

    The device can be equipped with up to three electrical functions: height adjustment, brake (standard on the REAL 8100 PLUS EL 24V Comfort model) and seat tilt (standard on the REAL 8100 PLUS EL 24V Comfort model). These are adjusted using the wireless remote control or wired hand control (optional).
  • Page 17: Seat

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Configurations and settings Button lock Activating and deactivating the button lock: 1. To activate the button lock, press and hold both of the directional buttons of the relevant function for at least three seconds.
  • Page 18: Manual Seat Tilt

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Configurations and settings 5.5. Manual seat tilt Manual seat tilt is available in the range of 15° forward to 8° backwards. The seat tilt is manually adjusted with a crank handle. Height adjustment is also available as an electrical function, see 5.3.
  • Page 19 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Configurations and settings Standard X-ray Back support mounted on the Standard X-ray backrest mechanism (see Figure 5.7). Mounting the back support: 1. Insert the back-support pole into the backrest mechanism.
  • Page 20 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Configurations and settings High Backrest with an adjustable cushion and headrest in Makrolon The Standard X-ray backrest mechanism’s back support is adjustable in terms of height (A) and the angle of the backrest mechanism is adjustable (B).
  • Page 21: Armrest Panel

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Configurations and settings 5.7. Armrest panel Armrest panels are available in three versions, ErgoMedic, Mobil (optional) and Extra soft (optional). Armrest panel upholstery is available in faux leather. Further details about upholstery and available colours are available on our website www.mercado.se.
  • Page 22: Armrest Mechanism

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Configurations and settings 5.8. Armrest mechanism The armrest mechanism is available as foldable armrests. Foldable armrests Foldable armrests have adjustable height (A) and width (B) and can be folded to the rear (C) (see Figure 5.14).
  • Page 23: Manual Brake

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Configurations and settings Base Plus Clinic 48 White The base has two brake legs, and it brakes backwards (see Figure 5.15). Figure 5.15. Base Plus Clinic 48 White. Protractor with rotation release The control is placed on the brake axle on the back of the base.
  • Page 24: Leg Support

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Configurations and settings Foot brake If the device is equipped with a foot brake, this is located on the base’s brake axle (see Figure 5.18). Activation and deactivation: 1. Push down to the locking position to brake.
  • Page 25 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Configurations and settings Cross leg support adapter The Cross Leg Support Adapter (see Figure 5.21) is mounted on the armrests’ width adjustment bar. The adapter can be mounted in two depth positions for different deep seats and be fine-tuned steplessly to 50 mm in depth.
  • Page 26: Individual Adaptation

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Configurations and settings 5.12. Individual adaptation Devices that have undergone changes outside of the above guidelines must be The device must not be equipped with any verified by Mercado Medic in order for...
  • Page 27: Important Safety Information

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Important safety information 6. Important safety information Our website www.mercado.se has information about any safety notices to the market or recalls of devices and accessories. 6.1. Standards met and classification...
  • Page 28: Warnings

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Important safety information 6.2. Warnings Warning! As a user, you must Warning! Always make sure to contact your distributor if the brake the device and lock the seat device exhibits impaired or changed rotation before the patient sits performance.
  • Page 29: Expected Service Life

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Important safety information Warning! Only tested and approved Warning! All parts of the device batteries and chargers from must be installed and fixed so Mercado Medic may be used with that there is no risk of small parts models with electrical functions.
  • Page 30: Reporting Of Adverse Events

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Important safety information The expected service life of accessories • when reconditioning and servicing have supplied with a Mercado Medic device is been carried out, 10 years unless otherwise stated in the •...
  • Page 31: Technical Information

    Warning! Repairs and other technical measures may only be carried out by personnel authorised by Mercado Medic. If this is not followed, the CE marking no longer applies and Mercado Medic may no longer have full device liability.
  • Page 32 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Technical information Device characteristics for all models REAL 8100 PLUS EL 24V Standard REAL 8100 PLUS EL 24V Comfort Width 480 mm Length 550 mm Total height 1210–1490 mm Seat height 460–740 mm...
  • Page 33: Symbols

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Technical information 7.1. Symbols The following symbols are used on the device controls, markings or in these instructions for use. For an overview of where symbols are placed, see Figures 7.1–7.3.
  • Page 34 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Technical information No. Labelling and instructions for use Warning Device classified as Type B applied part according to IEC 60601-1:2005 Protect from moisture Electrical components must be disposed of at a special...
  • Page 35: Servicing & Reconditioning

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Servicing & reconditioning 8. Servicing & reconditioning This section describes the inspection and troubleshooting of the device, information about battery replacement and instructions for reconditioning the device. The troubleshooting guide is aimed at all users of the device, and the section is otherwise aimed at those who handle these parts of the device lifecycle professionally.
  • Page 36: Troubleshooting Guide

    Servicing & reconditioning 8.1. Troubleshooting guide If none of the following actions address the problem that has occurred, service may be required. Contact your distributor or get in touch with Mercado Medic, see 1.1. Contact details. Troubleshooting for electrical functions Symptom...
  • Page 37 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Servicing & reconditioning Symptom Cause Action The electrical functions do The internal batteries of the Charge the device, see not work. The indicator shows device are discharged or 2.3. Charging. If charging a low battery level if the defective.
  • Page 38: Battery Replacement

    8.2. Battery replacement Warning! Repairs and other technical measures may only be carried out by personnel authorised by Mercado Medic. If this is not followed, the CE marking no longer applies and Mercado Medic may no longer have full device liability.
  • Page 39: Reconditioning And Periodic Maintenance

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Servicing & reconditioning 8.3. Reconditioning and periodic on all four wheels in the unbraked position, maintenance the device must be withdrawn from service immediately. Check the balance of the base...
  • Page 40 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Servicing & reconditioning When the battery is disconnected, it must charging outlet and wall socket. Wait at be charged every four months in order to least five seconds before disconnecting retain its functionality, see 2.3.
  • Page 41 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Servicing & reconditioning Area Reconditioning instructions Controls Make sure that the control buttons and controller are working and have no damage to the casing or cables. Contacts Check that cables and connectors are intact and properly secured.
  • Page 42 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Servicing & reconditioning Area Reconditioning instructions 4 Base Welds Check all welds carefully for signs of cracks, corrosion and movement. Ensure good lighting and preferably use a magnifying glass, as small cracks can be difficult to detect on black-painted bases.
  • Page 43 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Servicing & reconditioning Area Reconditioning instructions Controls Make sure that all knobs and handles on the seat frame are working and that they lock correctly. Crank-controlled seat tilt If the chair is equipped with a crank-controlled seat tilt, check that there is no play and that all screws are tightened.
  • Page 44 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Servicing & reconditioning Area Reconditioning instructions 10 Accessories 10.1 Restoration Remove the accessories that should not be attached to the device in the basic version, see 5.2. Basic design.
  • Page 45: Instructions For Destruction

    Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Instructions for destruction 9. Instructions for destruction Devices permanently decommissioned must be dismantled and sorted in a correct and safe manner. The website www.mercado.se/en/mercado-document there are installation instructions that can also be used to dismantle the device's components. The components should then be discarded in the relevant manner, see 9.1.
  • Page 46 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Instructions for destruction This page has been deliberately left blank 21-08993-UK-00...
  • Page 47 Instructions for use for REAL 8100 PLUS X-ray medical clinic chairs Instructions for destruction This page has been deliberately left blank 21-08993-UK-00...

This manual is also suitable for:

Real 8100 plus el 24v standardReal 8100 plus el 24v comfort