Page 1
PRESSURE FEED SPRAY GUN PRODUCT INFORMATION The CPR-FE gun comes equipped with both a pressure reduced air cap 23-2101 and a HVLP air cap 23-1301 for areas requiring HVLP compliance. 23-2101 - consumes 11 cfm at 29 psi gun inlet.
Page 2
CPR-FE Operation and Maintenance Instructions for Spray Guns Operation 1. Connect air supply hose at handle of gun. 2. Connect a pressurized fluid supply to the gun fluid inlet. 3. Fluid flow can be controlled using the fluid control knob, this restricts flow by limiting needle travel. It is best to control fluid flow by proper selection of fluid orifice size and use the fluid control knob to “fine tune flow rate”.
Page 3
HVLP AIR CAP TEST GAGES 23-1301-G CPR-FE ITEM NO. PART NO. DESCRIPTION ITEM NO. PART NO. DESCRIPTION See Air Cap Chart Air Cap** 60-1312 Fluid Control Knob See Air Cap Chart Fluid Nozzle Tip** See Air Cap Chart Fluid Needle**...
Page 4
FLUID NOZZLE / AIR CAP SELECTION CHARTS CPR-FE Series - Pressure Feed Guns CPR-FE HVLP/PRESSURE REDUCED SPRAY GUN FLUID ORIFICE x MAXIMUM MATERIAL TYPE AIR CAP PATTERN WIDTH Very Thin 0.8 mm x 2101 or 1301 23-2101 13" 23-2101 11 CFM less than 16 sec.