NOTE!
Mounting in thermowell only with plastic screw connection.
1. Pinch together the plastic screw connection on the probe cable.
Important: Do not mount the plastic screw connection into the recesses (beading) on the tempera-
ture probe sleeve.
2. Push the plastic screw connection up to the probe tube. Screw the probe into the immersion sleeve.
3. Tighten the screw connection with a tightening torque of 3 to 5 Nm (hand-tight).
Make sure that the probe is mounted securely in the immersion sleeve (probe tip must sit on the base
of the immersion sleeve).