Timer Adjustment (Control Board) - Bunn G9-2T DBC Installation And Operating Manual

Bunn g9-2t dbc: operating manual
Hide thumbs Also See for G9-2T DBC:
Table of Contents

Advertisement

Three different batch settings are selectable for each hopper. Each batch is independently adjustable by set-
ting the length of time a slide gate opens to allow beans to drop into the grinding chamber. A second time setting
for each batch determines how long the grind motor continues to run after the slide gate closes. This time is set
long enough to insure that all the beans dropped into the grind chamber are ground and dispensed.
1. Determine the grind setting. (The factory setting is drip, to determine other settings, refer to the previous
section.)
2. Use the table below to find approximate timer setting for the grind and amount of coffee desired.
3. To enter the setup mode and make an adjustment, press and hold the hidden programming pad under the
®. One of the batch indicators will begin to flash off and on. At this point, release the ® button.
4. Push the hopper/batch selector button for the batch to be adjusted. Note that the digital display shows the
current slide gate time setting (in seconds).
5. To increase the time, press the GRIND button. To decrease, press the STOP button.
6. To change the chamber clean-out time, press the same batch button again and note that the indicator light
begins to blink more rapidly and the display shows the current clean-out time.
7. To increase the time, press the GRIND button. To decrease it, press the STOP button.
8. After the cleanout time has been entered, press another batch pad and repeat steps 4 to 7. Otherwise, to exit
the programming mode, press and release the ® pad and the grinder returns to the normal operating mode,
using the new settings.
NOTE: While in the setup mode, if no buttons are pushed for 60 seconds, the grinder will return to normal opera-
tions, retaining any settings made while in the setup mode.

TIMER ADJUSTMENT (CONTROL BOARD)

APPROXIMATE TIMER SETTINGS IN SECONDS
Weight
Fine
(ounces)
(7*)
1.5
1.75
2.0
2.25
2.5
2.75
3.0
3.25
4.0
6.0
8.0
10.0
12.0
14.0
16.0
*Hash mark settings. Refer to Burr Adjustment section.
Drip
Regular
(8*)
(12*)
0.5
0.5
0.7
0.6
1.0
0.8
1.4
1.4
1.9
1.8
2.4
2.2
2.9
2.7
3.3
3.1
4.8
4.4
8.6
7.9
12.0
11.5
15.7
15.1
19.6
18.5
23.5
22.0
27.0
25.3
8
0.5
0.6
0.8
1.2
1.6
2.0
2.5
2.9
4.0
7.5
10.9
14.1
17.5
20.9
24.3
33736 030205

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents