Download Print this page
Giatsu GIA-S09AR2B-R32 Owner's Manual
Hide thumbs Also See for GIA-S09AR2B-R32:

Advertisement

ES
EN
FR
PT
IT
AROMA 2 R32
GIA-S09AR2B-R32 | GIA-S12AR2B-R32
GIA-S18AR2B-R32 | GIA-S24AR2B-R32
Por favor lea atentamente este manual antes de usar este producto.
Please, read carefully this manual before using the product.
Avant d'utiliser l'équipement, lisez attentivement les instructions.
Por favor leia atentamente este manual antes de usar o equipamento.
Per favore leggere attentamente questo manuale prima di utilizzare questo prodotto.
G r a c i a s | T h a n k y o u | M e r c i | O b r i g a d o | G r a z i e
OWNER'S MANUAL
SPLIT 1X1

Advertisement

loading

Summary of Contents for Giatsu GIA-S09AR2B-R32

  • Page 1 OWNER’S MANUAL SPLIT 1X1 AROMA 2 R32 GIA-S09AR2B-R32 | GIA-S12AR2B-R32 GIA-S18AR2B-R32 | GIA-S24AR2B-R32 Por favor lea atentamente este manual antes de usar este producto. Please, read carefully this manual before using the product. Avant d’utiliser l’équipement, lisez attentivement les instructions.
  • Page 2 ENGLISH OWNER’S MANUAL SPLIT 1X1 AROMA 2 R32 GIA-S09AR2B-R32 | GIA-S12AR2B-R32 GIA-S18AR2B-R32 | GIA-S24AR2B-R32...
  • Page 3: Table Of Contents

    Table of contents Owner’s Manual 0. Safety Precautions ..................24 1. Unit Specifications and Features ..............28 2. Manual Operation (Without Remote) ............33 3. Care and Maintenance ................... 34 4. Troubleshooting ..................... 36 5. European Disposal Guidelines..............40...
  • Page 4: Safety Precautions

    Precautions Read safety precautions before operation and installation Improper installation due to ignoring instructions can cause serious damage or injury. The severity of possible damage or injury is classified as a WARNING or CAUTION. WARNING CAUTION This symbol indicates the possibility of property This symbol indicates the possibility of personal injury.
  • Page 5 CLEANING AND MAINTENANCE WARNINGS • Turn off the device and turn off the power before cleaning. Otherwise, it may cause an electric shock. • Do not clean the air conditioner with excessive amounts of water. • Do not clean the air conditioner with flammable cleaning products. Flammable cleaning agents can cause fires or deformations.
  • Page 6 WARNINGS FOR PRODUCT INSTALLATION Installation must be performed by an authorized dealer or specialist. A faulty installation can cause water leakage, electric shock or fire. Installation must be carried out in accordance with the instructions for this. Improper installation can cause water leakage, electric shock or fire.
  • Page 7 WARNING FOR THE USE OF R-32 REFRIGERANT • When flammable refrigerant is used, the appliance must be stored in a well ventilated area where the size of the room corresponds to the area of ​ ​ t he room as specified for its operation. For R-32 refrigerant models: The device must be installed, operated and stored in a room with a surface area greater than .
  • Page 8: Unit Specifications And Features

    Unit Specifications and Features Unit Parts Front Panel Power Cable (Some Units ) Louver Remote Control Remote Holder (Some Units) Display window fresh defrost run timer fresh “ ” when FRESH feature is turned on(some units). ” defrost when defrosting. “...
  • Page 9 Achieving Optimal Performance Optimal performance for the COOL, HEAT, and DRY modes can be achieved in the following temperature ranges. When your air conditioner is used outside of these ranges, certain safety protection features will activate and cause the unit to perform less than optimally.
  • Page 10 • Wi-Fi Control (some units) For a detailed explanation of each Wi-Fi control allows you to control your function, refer to the Remote Control air conditioner using your mobile phone Manual. and a Wi-Fi connection. Other Features • Louver Angle Memory(some units) •...
  • Page 11 Setting Angle of Air Flow • Setting vertical angle of air flow While the unit is on, use the SWING / DIRECT button to set the direction (vertical angle) of airflow. 1. Press the SWING /DIRECT button once to activate the louver. Each time you press the button, it will adjust the louver by 6°.
  • Page 12 Sleep Operation • The SLEEP function is used to decrease energy use while you sleep (and don’t need the same temperature settings to stay comfortable). This function can only be Press the SLEEP button activated via remote control. when you are ready to go to sleep. When in COOL mode, the unit will increase the temperature by 1°C (2°F) after 1 hour, and will increase an additional 1°C (2°F) after...
  • Page 13: Manual Operation (Without Remote)

    Manual Operation (Without Remote) How to operate your unit without CAUTION the remote control The manual button is intended for testing In the event that your remote control fails to purposes and emergency operation only. work, your unit can be operated manually Please do not use this function unless the with the MANUAL CONTROL button remote is lost and it is absolutely necessary.
  • Page 14: Care And Maintenance

    Care and Maintenance 6. Rinse the filter with fresh water, then Cleaning Your Indoor Unit shake off excess water. BEFORE CLEANING 7. Dry it in a cool, dry place, and refrain OR MAINTENANCE from exposing it to direct sunlight. ALWAYS TURN OFF YOUR AIR CONDITIONING 8.
  • Page 15 Maintenance – Long Periods of CAUTION Non-UseIf you • Before changing the filter or cleaning, If you plan not to use your air conditioner for turn off the unit and disconnect its power supply. an extended period of time, do the following: •...
  • Page 16: Troubleshooting

    Troubleshooting SAFETY PRECAUTIONS If ANY of the following conditions occurs, turn off your unit immediately! • The power cord is damaged or abnormally warm • You smell a burning odor • The unit emits loud or abnormal sounds • A power fuse blows or the circuit breaker frequently trips •...
  • Page 17 Issue Possible Causes A rushing air sound may occur when the louver resets its position. The indoor unit makes noises A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’s plastic parts. Low hissing sound during operation: This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units.
  • Page 18 Troubleshooting When troubles occur, please check the following points before contacting a repair company. Problem Possible Causes Solution Temperature setting may be higher than Lower the temperature setting ambient room temperature The heat exchanger on Clean the affected heat exchanger the indoor or outdoor unit is dirty Remove the filter and clean it...
  • Page 19 Problem Possible Causes Solution Wait for the power to Power failure be restored The power is turned off Turn on the power The fuse is burned out Replace the fuse The unit is not working Remote control batteries Replace batteries are dead The Unit’s 3-minute Wait three minutes...
  • Page 20: European Disposal Guidelines

    European Disposal Guidelines European Guidelines for Disposal This mark on a product or in its documentation indicates that your electrical waste and electrical waste equipment should not be mixed with household waste. Correct disposal of this product (Waste electrical and electronic equipment) This appliance contains refrigerant and other potentially hazardous materials.
  • Page 21 C/ Industria, 13, Polígono Industrial El Pedregar. 08160 Montmeló. Barcelona (España) Tel (0034) 93 390 42 20 - Fax (0034) 93 390 42 05 info@giatsu.com - www.giatsu.com FRANCE PORTUGAL ITALIA info.fr@giatsu.com info.pt@giatsu.com info.it@giatsu.com L L L I I I T T T H H H U U U A A A N N N I I I A A A info@giatsu.lt...