Single/Dual Volt Models - Bunn AXIOM 35-3 Installation & Operating Manual

Bunn axiom 35-3: user guide
Table of Contents

Advertisement

Requirements for brewers with an attached cord set are as follows:
Note: This electrical service re-
quires 2 current carrying conduc-
tors (Neutral, and L1) and a separate
conductor for earth ground.
NEUTRAL
WHITE
WHITE
N
NEUTRAL
L1 BLACK
L1
L1 BLACK
GREEN
G
120V 2 WIRE + GROUND
Requirements for brewers without an attached cord set are as follows:
Note: This electrical service
require 3 current carrying
conductors (Neutral, L1 and
L2) and a separate conductor
for earth ground
L2 RED
L2 RED
L2
NEUTRAL
WHITE
WHITE
N
NEUTRAL
L1 BLACK
L1 BLACK
L1
GREEN
G
120/208-240V 3 WIRE + GROUND
L2 RED
L1 BLACK
240V 2 WIRE + GROUND
ELECTRICAL REQUIREMENTS
Single & Dual Volt Models
POWER CORD
120V AC
Single phase models
POWER CORD
120/208 & 120/240V AC
Single phase models
A &B Models
POWER CORD
L2 RED
L2
L1
L1 BLACK
GREEN
G
L2 RED
NEUTRAL BLUE
N
L1 BLACK
L1
L1 BROWN
GREEN/YELLOW
G
230V 2 WIRE + GROUND
Page 5
Dual Voltage Switch
in 120V position
120V
120/208-240V
For Supply Connections, Use No. 12 AWG
Wires Suitable For At Least 90°C (194°F)
FOR USE ONLY ON AN
INDIVIDUAL BRANCH
CIRCUIT RATED 20 AMPS
Dual Voltage Switch in
120/208-240V position
120V
120/208-240V
For Supply Connections, Use No. 12 AWG
Wires Suitable For At Least 90°C (194°F)
FOR USE ONLY ON AN
INDIVIDUAL BRANCH
CIRCUIT RATED 20 AMPS
POWER CORD
39130 113009