Eaton Vickers FCGT-02-A-11 Series Overhaul Manual page 10

Remote flow control valves
Table of Contents

Advertisement

Torque Motor Coil
Location
Location
Coil "A"
Coil "B"
Coil located next to the
armature connection nut
Table 4. Coil location and wiring code to male electrical connec-
tor (Item 4, Figure 3).
1
7. Remove a
/
inch of insulation from the ends of the
4
wires, then install a short piece of spaghetti sleeve over each
wire end and slide back on the wire. Position the wire ends up
and slide a new gasket (5) over the wires. Tin each wire end
with solder, then insert wires one at a time into the proper pin
of connector (4) and solder. Slide the sleeve over the pin after
solder has cooled.
POWER
SUPPLY
Polarity for
movement of
armature nut
in direction
of arrow
stamped on
torque motor.
NOTE: Reversal
of supply will
reverse
movement of
armature.
Figure 5. Schematic diagram of possible wiring connections to a Torque Motor.
10
Color Code Versus
Connector Pin
Red
Coded
A
B
D
C
+
PARALLEL
CONNECTION
SERIES
AIDING
CONNECTION
+
+
DIFFERENTIAL
+
CONNECTOR
CABLE
Coil resistance,
Series
ohms/wire code
aiding
40 / Yellow
150 ma
280 / White
50 ma
2200 / Blue
20 ma
5300 / Black
12.5 ma
Table 5. Input current required for max. armature deflection of
0.020 inch.
8. Assemble connector to the body with four screws. (3).
Cover (7), screws (8), and washers (9) will be
installed following test and calibration, Section VII.
A
TORQUE MOTOR
B
C
D
A
A
B
B
C
C
D
D
A
B
C
D
MALE CONNECTOR
Parallel
Differential
300 ma
N/A
100 ma
100 ma
40 ma
40 ma
25 ma
25 ma
NOTE
A – Red
B – Coded
C – Coded
Coil "B"
(Next to
armature
nut)
D – Red

Advertisement