Technical Data - flowair T-box User Manual

Hide thumbs Also See for T-box:
Table of Contents

Advertisement

Available languages

Available languages

do modułu DRV lub Cube

TECHNICAL DATA

sterownik T-box
Name
Power supply
Way of control
Temperature adjustment
range
Operating temperature range
Temperature sensor
Protection degree
max. 800 m*
Installation
* Dotyczy łącznie wszystkich urządzeń podłączonych do sterownika T-box
** W przypadku urz ądzeń Cube adresy ustawia serwis podczas pierwszego uruchomienia
Casing
Max. number of connected
units
Dimensions (HxWxD)
T-box controller connection to
DRV module or Cube
T-box controller
max. 800 m*
* Applies to all devices connected to T-box controller in line
** In case of Cube devices addressing is beeing done by service during first startup
In the case, when T-box in BMS network is the last device, SW1
switch should be set in T120 position.
www.flowair.com
w modułach DRV**
moduł DRV
Description
24 VDC
moduł DRV
touch screen
lub Cube
+5 ÷ +45°C
0 ÷ +60°C
built-in
IP20
screen
on the wall
ABS plastic, RAL 9003
31
130 x 115 x 35 mm
DRV module
addressing**
DRV module
DRV module
or Cube
screen
DRV - SW1 ADDRESS SETTING
Address: 1
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 2
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 3
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 4
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 5
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 6
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 7
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 8
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 9
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1
Address: 10
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1
Address: 11
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1
Address: 12
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 13
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1
Address: 14
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1
Address: 15
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1
Address: 16
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
DRV - SW2 ADDRESS SETTING
Last DRV
SW 2
in line
Address: 17
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 18
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1
Address: 19
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1
Address: 20
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1
Address: 21
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1
Address: 22
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 23
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 24
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 25
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 26
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 27
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 28
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1
Address: 29
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Address: 30
1
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1
Address: 31
0
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
1 2 4 8 16 Y1
Others DRV
SW 2
in line
67

Advertisement

Chapters

Table of Contents
loading

Table of Contents