Power Supply
Model: (default) PWS-2K08F-1R, 2000W redundant modules, 80Plus Titanium level; Optional:1200W
AC Input
1000W: 100-127Vac / 50-60Hz
1800W: 200-220Vac / 50-60Hz
1980W: 220-230Vac / 50-60Hz
2000W: 220-240Vac / 50-60Hz
2000W: 230-240Vac / 50-60Hz
+12V
Max: 83A (100Vac-127Vac)
Max: 150A (200Vac-220Vac)
Max: 165A (220Vac-230Vac)
Max: 166A (220Vac-240Vac)
Max: 166A (230Vac-240Vac)
12V SB
Max: 3.5A / Min: 0A
DC Input
1300W: Input voltage opearates at -48Vdc
+12V
Max: 108.3A
12V SB
Max: 2.1A / Min: 0A
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 60º C (-40º to 140º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
Appendix C: System Specifications