Reset Of The Device; Led Operation; Technical Specifications - Elkron IT500CLOUD User Manual

Table of Contents

Advertisement

Available languages

Available languages

RESET OF THE DEVICE

Proceed as follows to reset the device:
From any keypad in the system, enter the Installer code in the "Maintenance" menu and
delete the device from the "Delete/Keypads" menu (the device was previously acquired as a
keypad, delete the one with the correct address. For more information, refer to the
MP500/xx control panel installation manual.
Disconnect the power supply of the device and reconnect it.
Hold down the programming button (PROG) for at least 10 seconds until the green LED
lights up fixed. Now release the button.
The green LED will remain fixed for a few moments and then flash once a second.
The device has performed the reset parameters.
At this point the device is ready to be acquired again.

LED OPERATION

Hardware Reset
Board reset in Access Point mode, not acquired
by control panel
Board reset in Access Point mode, acquired
Board connected to WiFi/LAN
a.
Network/IP address acquisition.
b.
Acquired network, searching for Elkron
Cloud/certificate.
c.
Network acquired, Cloud/certificate acquired

TECHNICAL SPECIFICATIONS

Nominal power voltage .................................................................................................. 9 ÷ 15 V
Rated Current ........................................................................................... 70mA ±30% @ 13,8 V
LAN baud rate ................................................................................................................... 10Mbps
WiFi baud rate ................................................................................................................... 54Mbps
Operating temperature............................................................................................. -10°C ÷ +40°C
Average relative humidity during operation ...................................................................... 25 ÷ 75%
Dimensions (w x h x d) ........................................................................................ 108 x 91 x 31mm
KEY LEGEND
Symbol
~
Status
Direct current power voltage
Alternating input voltage
Refer to the device installation manual
blink for 10 seconds
1 blink approximately every 2 seconds
2 slow blinks with an interval of 8 seconds
between sequences
2 slow blinks with an interval of 1 seconds
between sequences.
3 slow blinks with an interval of 1 seconds
between sequences.
3 slow blinks with an interval of 8 seconds
between sequences.
Explanation
IT500CLOUD
Led signaling