5 Use and Operation

5.1

Precautions

WARNING
Make sure that the discharged liquid cannot cause damage to persons or things.
WARNING: Electrical hazard
Check that the unit is properly connected to the mains power supply.
WARNING: Hot surface hazard
Motor housing may be very hot. Burn hazard. Do not touch.
NOTICE:
Dry run of the unit is prohibited, as this can destroy the bearings in a very short time.
NOTICE:
It is prohibited to operate the unit with the shut-off valve closed.
5.2

Before starting

Before ever starting the pump, verify that:
• The instructions in section 4 Installation on page 17 have been performed.
• The system has been flushed thoroughly to prevent foreign objects and impurities from
• The system has been filled and air purged (see section 5.4 Air purge on page 31).
5.3

First starting

1. Connect the plug to the mains.
• In case of models with timer, check that the green slider is in "On" position (see point 4 on
• In case of models without control knob, the pump starts to operate immediately.
• In case of models with control knob the unit stays idle (Standby mode) or starts to operate
Figure 14
2. With the unit in operation, check that:
• No liquid is leaking from the pipes.
• There is no unwanted noise or vibrations.
• Liquid is actually being pumped.
30
blocking the pump.
page 32).
depending on the position of the knob (see Figure 14 for the different scale layouts).