FireAngel WST-630 User Manual page 7

Hide thumbs Also See for WST-630:
Table of Contents

Advertisement

products within the Wi-Safe 2 range
"Learning in" (interlinking) your Smoke
Alarms:
The process below describes 'learning in'
two alarms into a network,
"Alarm 2"
1. Alarm 1: Install Alarm 1 as described
previously
2. Alarm 2: Install the base plate for Alarm 2
in one of the recommended locations Do
not fit the second alarm to its base plate
yet
3. Alarm 2: Using a pen, a paper clip that has
been opened out, briefly push and release
the learn button located in a circular hole in
the back of Alarm 2
The red LED next to the learn button will flash
briefly then light up for approximately five
seconds to show that it is ready to receive the
"learn in" signal. During these five seconds
you will need to briefly press the test button on
Alarm 1 to wirelessly interlink the two alarms
"Alarm 1" and
Circular hole
Alarm 1 will give an audible sound consisting of
2 cycles of 3 loud beeps
Alarm 2 The red LED on the wireless module
of Alarm 2 will flash to indicate that it has been
"learned-in" successfully
Note: If the test button is not pressed quickly
enough (before the red LED on the wireless
module of Alarm 2 has extinguished), the learn-
in process will fail If this happens, repeat the
process again, as described above
5. Fit Alarm 2 onto its base plate to
complete the installation
6. Additional alarms should be "learned-in"
the same way When learning in additional
alarms, any alarm already in the network,
can be used as 'Alarm 1' This means that
you can "learn-in" the additional alarm to
any alarm already in the network It will
then become part of the whole network
You do not have to "learn it in" to each
alarm in the network
7