FireAngel THERMOPTEK Wi-Safe 2 User Manual

FireAngel THERMOPTEK Wi-Safe 2 User Manual

Wireless interlink smoke alarm

Advertisement

User Manual
10 Year Life Wireless Interlink Smoke Alarm
ST-632 + W2-Module
TEST YOUR ALARM MONTHLY
Please retain this user manual for future reference
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the THERMOPTEK Wi-Safe 2 and is the answer not in the manual?

Questions and answers

Summary of Contents for FireAngel THERMOPTEK Wi-Safe 2

  • Page 1 User Manual 10 Year Life Wireless Interlink Smoke Alarm ST-632 + W2-Module TEST YOUR ALARM MONTHLY Please retain this user manual for future reference...
  • Page 2: Table Of Contents

    Note: This User Manual is also available in large text and other formats. Please call 0330 094 5830 for further information ST-632 + W2-Module GN5488R1 FireAngel Safety Technology Limited Vanguard Centre, Coventry CV4 7EZ UK www.fireangeltech.com Technical Support: 0330 094 5830 / EIRE dial 1-800 523171 Email: technicalsupport@fireangeltech.com...
  • Page 3: Introduction

    INTRODUCTION THERMOPTEK TECHNOLOGY Groundbreaking Thermoptek technology combines the very latest in optical sensing Thermoptek alarms “toast-proof” with thermal enhancement, providing faster meaning they can be positioned in areas response to both fire types eliminating the close to kitchens that may be affected by need for ionisation sources which can be cooking fumes.
  • Page 4 In order to achieve the earliest fire warning, 300mm from light fittings and walls. we recommend that a smoke alarm is fitted Ideally as central as possible in the room. in all rooms where the temperature is If positioning your smoke alarm on the normally between 4°C (40°F) and 38°C wall, the top of the detection element must (100°F).
  • Page 5: How To Install Your Smoke Alarm

    NOTE: The W2-Module in your ST-632 unit sleeping/resident rooms, providing the same enables the alarm to interlink with up to 50 conditions are met as for a single-family Wi-Safe 2 devices in a single network. residence. However, there must already be a primary fire detection system that meets HOW TO INSTALL YOUR regulatory requirements for common areas...
  • Page 6: Interlinking Your Smoke Alarms

    2. Install Base Plate 4. Test Your FireAngel smoke alarm Fit the base plate to the ceiling or wall using After fitting the alarm to the base plate, wait the screws provided. for 5 seconds for the alarm to settle, then test the alarm.
  • Page 7 Note: If the test button is not pressed quickly enough (before the red LED on the wireless Circular hole module of Alarm 2 has extinguished), the learn- in process will fail. If this happens, repeat the process again, as described above. 5.
  • Page 8: Operation

    The alarm will check its sounder once a to operate correctly. month. If the alarm is interlinked with a FireAngel Wireless Gateway unit via a Wi- Should your FireAngel smoke alarm enter a Safe 2 network, it will report the alarm status low battery condition, the unit will emit an into the Wireless Gateway.
  • Page 9: Led Indicators

    ST-632 LED Indicators Audible Red LED Amber LED Status Action required signal Flashes every 3 loud beeps Check if there is a fire hazard and Alarm second repeating vacate property Other alarm in Flashes once 3 loud beeps Check if there is a fire hazard and network in alarm every 45 seconds repeating...
  • Page 10: Alarm Test

    ALARM TEST NOTE: The test button accurately tests the alarm’s smoke sensing circuit, there is The alarm must be properly attached to the no need to test your alarm with smoke. If base plate before it can be tested. your smoke alarm fails to give an audible test signal, please refer immediately to the a) Press the test button in the centre and trouble shooting guide at the end of this...
  • Page 11 alarm silence function after making sure that there is no ongoing fire emergency situation. Do not block the vents on the alarm or disable the smoke alarm in any way, as this will remove your protection. Smoke alarms can sometimes react to cooking fumes or other non emergency situations.
  • Page 12: Sleep Easy

    you replace your alarm immediately, and certainly within 30 days, as your alarm may then have insufficient power to warn you of a real fire situation after this time. WARNING: Your smoke alarm cannot be silenced if the chirp is indicating a fault. In DANGER: Never ignore any alarm.
  • Page 13: Troubleshooting

    Undue force may result in damage to the smoke alarm or the base plate, or be removed from its both. For more information, contact your installer, or the FireAngel Technical base plate. Support Team between 9am - 5pm Monday – Friday.
  • Page 14 • Check that your smoke alarm is definitely the source of the beeping; ensure the noise isn’t coming from another alarm (smoke/carbon monoxide/gas/ burglar alarm) by process of elimination. Your FireAngel smoke alarm • If the brief beep is emitted once every 45 seconds, and the yellow LED is emits a brief beep flashing around the same time, this indicates that the battery is low.
  • Page 15: Maintenance

    WARNING: Your smoke alarm may false of 5 (five) years from the date of purchase. Provided alarm when it is being cleaned using a product is sent back to FireAngel Safety Technology vacuum cleaner. Limited with proof and date of purchase, FireAngel...
  • Page 16 FireAngel Safety Technology Limited shall not be liable in respect of the alarm originally purchased – that is for any incidental or consequential damages caused by from the date of original purchase and not from the the breach of any expressed or implied warranty.