24 Troubleshooting Guide
Always remove the fuse key and battery before carrying out any inspection, cleaning or maintenance.
Condition
LEDs on
Battery
Lawn mower cuts out
1 LED glows
during operation.
red.
3 LEDs glow
red.
Drive system cannot
be activated.
Runtime is too short.
Battery is not being
1 LED glows
charged even though
red.
LED on charger
glows green.
0458-818-8221-A
Possible Cause
Remedy
Battery too hot / too
► Remove the battery, @ 13.2.
cold.
► Allow the lawn mower and battery to cool down gradually at
Lawn mower too hot.
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
► Increase the cutting height, @ 18.1.
► Reduce drive system speed, @ 16.1.
► Push the mower forward more slowly.
Mowing blade is
► Increase the cutting height, @ 18.1.
blocked.
► Clean the lawn mower, @ 22.
► Switch on the lawn mower in lower grass.
Malfunction in lawn
► Remove the battery and reinsert it, @ 14
mower.
► Try to activate self-propel again, @ 16.1.
► If self-propel still does not work, do not attempt to use.
The lawn mower has a malfunction and must be checked by
a servicing dealer.
Battery not fully
► Charge the battery, @ 9.2.
charged.
Useful life of battery
► Have the battery checked by an authorized STIHL servicing
has been reached or
dealer.
exceeded.
Battery too hot / too
► Allow the battery to warm up or cool down gradually at
cold.
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
► Operate the charger only in enclosed, dry rooms at ambient
temperatures of 41 °F to 104 °F (5 °C to 40 °C).