GEM DG-2000 Series Operation Manual page 9

Standalone prox reader controller
Table of Contents

Advertisement

GEM
DG-2000 Series Standalone PROX Reader Controller Operation Manual
__________________________________________________________________________
Enter / Exit the Programming Mode
**
**
1.
Press:
Master Password or
(Default master password = 12345678)
**
**#
2.
Press:
3.
In ready mode, entering Master password enables door to open.
Reset to Factory Setting
* * 801#801#
1. Press:
* * 802#802#
2. Press:
Master Reset
First turn off the power of the controller. Keep the RTE and GND wires connected and then turn
on the power. Wait for 5 seconds. The reader will reset master password to "12345678" after 4
short and 1 long beeps.
Change Master Password
* * 9
Press:
New Master Password
NOTE: Master Password length is 1 to 8 digits
Change Door Common Access Password
* * 82
Press:
Common Access Password
Default Common Access Password is "111111"
NOTE: Common Access Password length is 1 to 6 digits
Setting User Modes
Install DG-2000US or DG-2100EU controller at outdoor area (Normal Mode)
* * 01#
Enter:
(Default Setting)
Require a Card AND Common Access Password entry
* * 04#
Enter:
Require a Card AND Common Access Password or Door Access PIN for entry (Default)
* * 05#
Enter:
Require a Door Access PIN for entry only
Install DG-2000US or DG-2100EU controller at indoor area
and install GEM Optional Reader at outdoor area (Secure Mode)
* * 02#
Enter:
- For DG-2000US or DG-2100EU requires a Card only (No Common Access Password for entry
required)
- For outdoor GEM Optional Reader requires a Card AND Common Access Password for entry
* * 03#
Enter:
For DG-2000US or DG-2100EU requires a Card (No Common Access Password for entry required)
or a Door Access PIN for entry
For outdoor GEM Optional Reader requires a Card AND Common Access Password or Door Access
PIN for entry
Setting Current Time
* * 83
Press:
HHMMSS
Setting Electrified Lock Release Time
* * 81
Press:
Electrified Lock Release Time (00 to 30 seconds)
Electrified lock release time default setting is 5 seconds
_______________________________________________________________________________________________________________
Version 1. 05-22-2015
#
(Use master card). Reader LED color is Yellow.
to exit or 30 seconds timeout to exit automatically to return to ready mode.
(Clear all users information and reset to factory setting)
(Remain users information but reset to factory setting)
#
New Master Password
#
#
HHMMSS
Gianni Industries, Inc.
#
#
Common Access Password #
#
Page 9 of 17

Advertisement

Table of Contents
loading

Table of Contents