Danfoss Optyma OP-MCRN030 Instructions Manual

Integral range
Hide thumbs Also See for Optyma OP-MCRN030:

Advertisement

Quick Links

Instructions
Condensing Units
Optyma™ Integral range
H
D
Optyma
by Danfoss
© Danfoss | DCS (CC) | 2018.07
50 Hz
OP-MCRN030
OP-MCRN038
OP-MCRN048
OP-MCRN054
OP-MCRN060
OP-MCRN068
OP-MCRN086
OP-MCRN096
OP-MCRN108
W
OP-MCRN121
OP-MCRN136
OP-MGRN108
OP-MGRN121
TM
OP-MGRN136
OP-MGRN171
OP-MGRN215
OP-MGRN242
OP-MGRN271
MBP application
Compressor
H
W
D
MTZ018
545
630
650
MTZ022
MTZ028
MTZ032
705
900
900
MTZ036
MTZ040
MTZ050
MTZ056
836.5 1200 800
MTZ064
MTZ072
MTZ080
MTZ064
MTZ072
693.5 1500 870
MTZ080
MTZ100
MTZ125
836.5 1500 870
MTZ144
MTZ160
LBP application
50 Hz
Compressor
H
OP-LCQN048
NTZ048
545
OP-LCQN068
NTZ068
705
OP-LCQN096
NTZ096
OP-LCQN108
NTZ108
836.5 1200 800
OP-LCQN136
NTZ136
OP-LGQN096
NTZ096
OP-LGQN108
NTZ108
693.5 1500 870
OP-LGQN136
NTZ136
OP-LGQN215
NTZ215
836.5 1500 870
OP-LGQN271
NTZ271
FRCC.PI.059.A1.02 | 1
W
D
630
650
900
900

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss Optyma OP-MCRN030

  • Page 1 836.5 1500 870 OP-MCRN121 MTZ072 OP-LGQN271 NTZ271 OP-MCRN136 MTZ080 OP-MGRN108 MTZ064 Optyma OP-MGRN121 MTZ072 693.5 1500 870 OP-MGRN136 MTZ080 OP-MGRN171 MTZ100 by Danfoss OP-MGRN215 MTZ125 836.5 1500 870 OP-MGRN242 MTZ144 OP-MGRN271 MTZ160 FRCC.PI.059.A1.02 | 1 © Danfoss | DCS (CC) | 2018.07...
  • Page 2 R407A Evaporating Temperature (°C) Evaporating Temperature (°C) R407C Evaporating Temperature (°C) LBP (Fig.1b) SH = 10 K , SC = 0 K R404A/R507 R452A Evaporating Temperature (°C) Evaporating Temperature (°C) 2 | © Danfoss | DCS (CC) | 2018.07 FRCC.PI.059.A1.02...
  • Page 3 Instructions 1 x coil height Min. clearance: 2 x unit length Fig.2 Fig.3 Fig.4 FRCC.PI.059.A1.02 © Danfoss | DCS (CC) | 2018.07 | 3...
  • Page 4 Instructions SINGLE PHASE MODELS THREE PHASE MODELS 4 | © Danfoss | DCS (CC) | 2018.07 FRCC.PI.059.A1.02...
  • Page 5 Instructions Factory setting For R404A models HP (bar) LP (bar) FRCC.PI.059.A1.02 © Danfoss | DCS (CC) | 2018.07 | 5...
  • Page 6: Table Of Contents

    CFC, HCFC refrigerants. holes in the pipe work after installation. sonnel, in paying close attention to potential pressure-related hazards and heeding the pres- 6 | © Danfoss | DCS (CC) | 2018.07 FRCC.PI.059.A1.02...
  • Page 7: Leak Detection

    FRCC.PI.059.A1.02 © Danfoss | DCS (CC) | 2018.07 | 7...
  • Page 8: Start Up

    - Verify that safety devices are operational and check the power lead connections and all sui- mance characteristics as the original one. properly set. table capacitors on single-phase models. If these 8 | © Danfoss | DCS (CC) | 2018.07 FRCC.PI.059.A1.02...
  • Page 9: User Advisory

    Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trade- marks in this material are property of the respective companies.