d. Follow the tubing from the solenoids to the top of the machine ensuring
there are no obstructions or kinking in the tubes.
7. If all these items are operating properly and still no solution is flowing, contact
Sybaritic Customer Service.
Cleaning Procedure
1. Replace clear solution tip on hand set with blue cleaning tip.
2. To perform cleaning, remove Solution #1 & #3 bottles. Fill the white\opaque
cleaning solution bottle with warm distilled water.
3. Install the hose and cap from one of the solution bottles on the cleaning bottle
and connect to the S1 port on the top of the machine.
4. Open the flow control knob on the side of the machine to the fully open
position.
5. Turn on the S1 solution switch and let run continuously for 5 minutes.
6. Refill the cleaning solution bottle if necessary with warm distilled water.
7. Connect the hose of the cleaning bottle to the S3 port on the top of the
machine.
8. Turn on the S3 solution switch and let run continuously for 5 minutes.
18