Section 4. Installing The Jandy Truguard - Jandy TruGuard Installation And Operation Manual

Hide thumbs Also See for TruGuard:
Table of Contents

Advertisement

Available languages

Available languages

Jandy
TruGuard
| Installation & Operation Manual
®
Section 4.
The Jandy TruGuard installs on your pool's return line.
1.
Determine the location to install the Jandy TruGuard. It must be
installed:
• After the filter on the main return to the pool.
• Before or after the heater (downstream of solar heating systems).
• Before check valve to any chemical dispenser or the discharge of any
off-line chemical dispenser.
Pump
2.
Locate an area on the return line that is at least 8" to install the Jandy
TruGuard.
3.
Turn OFF the pool pump. Your pump/filter system is operated
under pressure. The pressure must be released before you begin
work. Please refer to the pump/filter owner's manual for further
instructions.
4. Close any valves. If your pool filtration equipment is below the water
level of the pool, you will either need to close the return valve or
use winterizing plugs at the skimmer and return fittings to prevent
excessive water loss.
5.
Remove the cartridge from the housing and plumb the housing into the
pipe, making sure that the flow indicator arrows on the housing match
the flow direction of the water. Pipes must be clean and dry before
gluing.
NOTE:
If the flow direction of the water does not match the arrows on the housing,
the unit will not function properly. Housing can be oriented horizontally or
vertically. For ease of servicing and maintenance, it is recommended that
the housing be installed horizontally with the cartridge facing up.
Installing the Jandy TruGuard
Filter
Jandy
TruGuard
ENGLISH
Heater
Chlorinator
Check
Valve
Intake Line
Page 5
Return Line

Advertisement

Chapters

Table of Contents
loading

Table of Contents